An analytical method for simultaneous determination of total polyphenol content (TPC) and antioxidant activity (AA) of wines (white and red wines) and oenological tannins, using a flow injection system with sequential diode array and electrochemical amperometry detectors (DAD-ECD), was proposed. The signal at 280 nm provided aggregate data for TPC. The anodic peak related to wine phenolic oxidation was scanned using pulsed integrated amperometry over the potential of 800 mV vs. Ag/AgCl, to obtain AA. Serial dilutions avoided the poisoning at the glassy carbon (GC) electrode and the linear response obtained with both detectors was compared with spectrophotometric assays commonly used in oenology laboratory. Intraday and interday analytical repetitions showed a good repeatability and reproducibility (relative standard deviation RSD < 6% for both detectors), and the satisfactory relationship between the proposed coupled flow injection/DAD-ECD and the classic UV methods (R2TPC= 0.9967; R2DPPH= 0.9621) confirmed the efficacy of flow injection analysis with a coupled detection system, for the reliable quality control of wine and wine-related products.

Ricci, A., Teslic, N., Petropolus, V., Parpinello, G.P., Versari, A. (2019). Fast Analysis of Total Polyphenol Content and Antioxidant Activity in Wines and Oenological Tannins Using a Flow Injection System with Tandem Diode Array and Electrochemical Detections. FOOD ANALYTICAL METHODS, 12, 347-354 [10.1007/s12161-018-1366-z].

Fast Analysis of Total Polyphenol Content and Antioxidant Activity in Wines and Oenological Tannins Using a Flow Injection System with Tandem Diode Array and Electrochemical Detections

Ricci, Arianna
Writing – Original Draft Preparation
;
Teslic, Nemanja
Membro del Collaboration Group
;
Parpinello, Giuseppina Paola
Writing – Review & Editing
;
Versari, Andrea
Supervision
2019

Abstract

An analytical method for simultaneous determination of total polyphenol content (TPC) and antioxidant activity (AA) of wines (white and red wines) and oenological tannins, using a flow injection system with sequential diode array and electrochemical amperometry detectors (DAD-ECD), was proposed. The signal at 280 nm provided aggregate data for TPC. The anodic peak related to wine phenolic oxidation was scanned using pulsed integrated amperometry over the potential of 800 mV vs. Ag/AgCl, to obtain AA. Serial dilutions avoided the poisoning at the glassy carbon (GC) electrode and the linear response obtained with both detectors was compared with spectrophotometric assays commonly used in oenology laboratory. Intraday and interday analytical repetitions showed a good repeatability and reproducibility (relative standard deviation RSD < 6% for both detectors), and the satisfactory relationship between the proposed coupled flow injection/DAD-ECD and the classic UV methods (R2TPC= 0.9967; R2DPPH= 0.9621) confirmed the efficacy of flow injection analysis with a coupled detection system, for the reliable quality control of wine and wine-related products.
2019
Ricci, A., Teslic, N., Petropolus, V., Parpinello, G.P., Versari, A. (2019). Fast Analysis of Total Polyphenol Content and Antioxidant Activity in Wines and Oenological Tannins Using a Flow Injection System with Tandem Diode Array and Electrochemical Detections. FOOD ANALYTICAL METHODS, 12, 347-354 [10.1007/s12161-018-1366-z].
Ricci, Arianna; Teslic, Nemanja; Petropolus, Violeta-Ivanova; Parpinello, Giuseppina Paola*; Versari, Andrea
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/647964
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 10
social impact