A rapid method for the simultaneous measurement of gluconic acid and glycerol, two important chemical markers of grape infection, was developed using Fourier-transform mid-infrared (FT-MIR) spectroscopy. The method used a combination of FT-MIR with partial-least squares (PLS) regression and compositional data of Trebbiano and Sangiovese grapes obtained with high performance ion-exchange chromatography (HPLC). A total of 320 grape samples were analyzed, including grapes hand picked in the vineyards (200 samples) and mechanically sampled from trucks upon arrival at the wineries (120 samples). Gluconic acid and glycerol increased with increasing percentage of grape infection assessed by visual inspection (r = 0.928). The best result was obtained for gluconic acid (R2 = 0.979; RMSECV = 0.63; RPD = 7.0),), indicating that FT-MIR was suitable for process control.

Versari A., Parpinello G.P., Mattioli A.U., Galassi S. (2008). Determination of grape quality at harvest using Fourier transform mid-infrared spectroscopy and multivariate analysis. AMERICAN JOURNAL OF ENOLOGY AND VITICULTURE, 59, 317-322.

Determination of grape quality at harvest using Fourier transform mid-infrared spectroscopy and multivariate analysis.

VERSARI, ANDREA;PARPINELLO, GIUSEPPINA PAOLA;MATTIOLI, ALESSIA UMBERTA;GALASSI, SERGIO
2008

Abstract

A rapid method for the simultaneous measurement of gluconic acid and glycerol, two important chemical markers of grape infection, was developed using Fourier-transform mid-infrared (FT-MIR) spectroscopy. The method used a combination of FT-MIR with partial-least squares (PLS) regression and compositional data of Trebbiano and Sangiovese grapes obtained with high performance ion-exchange chromatography (HPLC). A total of 320 grape samples were analyzed, including grapes hand picked in the vineyards (200 samples) and mechanically sampled from trucks upon arrival at the wineries (120 samples). Gluconic acid and glycerol increased with increasing percentage of grape infection assessed by visual inspection (r = 0.928). The best result was obtained for gluconic acid (R2 = 0.979; RMSECV = 0.63; RPD = 7.0),), indicating that FT-MIR was suitable for process control.
2008
Versari A., Parpinello G.P., Mattioli A.U., Galassi S. (2008). Determination of grape quality at harvest using Fourier transform mid-infrared spectroscopy and multivariate analysis. AMERICAN JOURNAL OF ENOLOGY AND VITICULTURE, 59, 317-322.
Versari A.; Parpinello G.P.; Mattioli A.U.; Galassi S.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/61813
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 36
social impact