A total of 287 olive lots and 161 olive oil samples were analyzed for fat content, moisture and free acidity, using a Fourier transform near-infrared (FT-NIR) instrument located in an industrial mill. Samples having a wide range of both reference values and olive lot sizes (from ,0.5 to .4 t) were collected at three industrial mill plants, located in the same Italian region, which utilize different technological equipment for virgin olive oil production. Olive paste spectra were acquired in diffuse reflectance, while oil samples were measured in transmission. Calibration models for oil content and moisture of olives as well as free acidity of virgin olive oils were developed using partial least squares (PLS) regression, first derivative and straight line subtraction. Results of calibration and validation of the PLS models selected were good. The PLS results indicate good similarity between data obtained from FT-NIR and reference laboratory methods, allowing a rapid and less expensive screening analysis. Unfortunately, the correlation between the oil yield values recorded for all olive lots at the industrial mills and the oil content predicted by FT-NIR was not satisfactory (R2 = 0.605).

In-process monitoring in industrial olive mill by means of FT-NIR / A. Bendini; L. Cerretani; F. Di Virgilio; P. Belloni; G. Lercker; T. Gallina Toschi. - In: EUROPEAN JOURNAL OF LIPID SCIENCE AND TECHNOLOGY. - ISSN 1438-7697. - STAMPA. - 109:(2007), pp. 498-504. [10.1002/ejlt.200700001]

In-process monitoring in industrial olive mill by means of FT-NIR

BENDINI, ALESSANDRA;CERRETANI, LORENZO;LERCKER, GIOVANNI;GALLINA TOSCHI, TULLIA
2007

Abstract

A total of 287 olive lots and 161 olive oil samples were analyzed for fat content, moisture and free acidity, using a Fourier transform near-infrared (FT-NIR) instrument located in an industrial mill. Samples having a wide range of both reference values and olive lot sizes (from ,0.5 to .4 t) were collected at three industrial mill plants, located in the same Italian region, which utilize different technological equipment for virgin olive oil production. Olive paste spectra were acquired in diffuse reflectance, while oil samples were measured in transmission. Calibration models for oil content and moisture of olives as well as free acidity of virgin olive oils were developed using partial least squares (PLS) regression, first derivative and straight line subtraction. Results of calibration and validation of the PLS models selected were good. The PLS results indicate good similarity between data obtained from FT-NIR and reference laboratory methods, allowing a rapid and less expensive screening analysis. Unfortunately, the correlation between the oil yield values recorded for all olive lots at the industrial mills and the oil content predicted by FT-NIR was not satisfactory (R2 = 0.605).
2007
In-process monitoring in industrial olive mill by means of FT-NIR / A. Bendini; L. Cerretani; F. Di Virgilio; P. Belloni; G. Lercker; T. Gallina Toschi. - In: EUROPEAN JOURNAL OF LIPID SCIENCE AND TECHNOLOGY. - ISSN 1438-7697. - STAMPA. - 109:(2007), pp. 498-504. [10.1002/ejlt.200700001]
A. Bendini; L. Cerretani; F. Di Virgilio; P. Belloni; G. Lercker; T. Gallina Toschi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/45446
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 58
  • ???jsp.display-item.citation.isi??? 56
social impact