A flexible, fully organic detector for proton beams is presented here. The detector operates in the indirect mode and is composed of a polysiloxane-based scintillating layer coupled to an organic phototransistor, that is assessed for flexibility and low-voltage operation (V = -1 V), with a limit of detection of 0.026 Gy min(-1). We present a kinetic model able to precisely reproduce the dynamic response of the device under irradiation and to provide further insight into the physical processes controlling it. This detector is designed to target real-time and in-situ dose monitoring during proton therapy and demonstrates mechanical flexibility and low power operation, assessing its potential employment as a personal dosimeter with high comfort and low risk for the patient. The results show how such a proton detector represents a promising tool for real-time particle detection over a large area and irregular surfaces, suitable for many applications, from experimental scientific research to innovative theranostics.

Calvi, S., Basiricò, L., Carturan, S.M., Fratelli, I., Valletta, A., Aloisio, A., et al. (2023). Flexible fully organic indirect detector for megaelectronvolts proton beams. NPJ FLEXIBLE ELECTRONICS, 7(1), 1-11 [10.1038/s41528-022-00229-w].

Flexible fully organic indirect detector for megaelectronvolts proton beams

Basiricò, Laura
Co-primo
;
Fratelli, Ilaria;Ciavatti, Andrea;Verdi, Matteo;Mariucci, Luigi;Fraboni, Beatrice
2023

Abstract

A flexible, fully organic detector for proton beams is presented here. The detector operates in the indirect mode and is composed of a polysiloxane-based scintillating layer coupled to an organic phototransistor, that is assessed for flexibility and low-voltage operation (V = -1 V), with a limit of detection of 0.026 Gy min(-1). We present a kinetic model able to precisely reproduce the dynamic response of the device under irradiation and to provide further insight into the physical processes controlling it. This detector is designed to target real-time and in-situ dose monitoring during proton therapy and demonstrates mechanical flexibility and low power operation, assessing its potential employment as a personal dosimeter with high comfort and low risk for the patient. The results show how such a proton detector represents a promising tool for real-time particle detection over a large area and irregular surfaces, suitable for many applications, from experimental scientific research to innovative theranostics.
2023
Calvi, S., Basiricò, L., Carturan, S.M., Fratelli, I., Valletta, A., Aloisio, A., et al. (2023). Flexible fully organic indirect detector for megaelectronvolts proton beams. NPJ FLEXIBLE ELECTRONICS, 7(1), 1-11 [10.1038/s41528-022-00229-w].
Calvi, Sabrina; Basiricò, Laura; Carturan, Sara M.; Fratelli, Ilaria; Valletta, Antonio; Aloisio, Alberto; De Rosa, Stefania; Pino, Felix; Campajola, ...espandi
File in questo prodotto:
File Dimensione Formato  
s41528-022-00229-w.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 2.81 MB
Formato Adobe PDF
2.81 MB Adobe PDF Visualizza/Apri
admi759-sup-0001-suppmat.pdf

accesso aperto

Tipo: File Supplementare
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 953.2 kB
Formato Adobe PDF
953.2 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/960652
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
social impact