Due to the SARS-CoV-2 pandemic renewed attention has been directed towards viral neutralization assays and neutralizing antibodies quantification, for vaccine pre-clinical trials and determining vaccine efficacy over time. The gold standard to assess antibody titer is the plaque reduction neutralization test, an end-point assay which evaluates the highest serum antibody dilution that neutralizes viral replication, by inspecting the cytopathic effect induced on cell cultures. Here, we use planar, PEDOT:PSS-based organic electrochemical transistors for real-time, remote-controlled, reliable and fast electrical monitoring of the cytopathic effect induced by SARS29 CoV-2 on Vero E6 cell lines, allowing the quantification of serum neutralizing titer. Our low-cost and scalable device has the potential to speed-up large-scale viral neutralization screening without the need for cancerous staining or highly specialized operators. Finally, the technology could be easily transferred to assess neutralizing antibody response towards different viruses in their permissive cell substrates.

Decataldo F., Grumiro L., Marino M.M., Faccin F., Giovannini C., Brandolini M., et al. (2022). Fast and real-time electrical transistor assay for quantifying SARS-CoV-2 neutralizing antibodies. COMMUNICATIONS MATERIALS, 3(1), 1-9 [10.1038/s43246-022-00226-6].

Fast and real-time electrical transistor assay for quantifying SARS-CoV-2 neutralizing antibodies

Decataldo F.;Giovannini C.;Brandolini M.;Dirani G.;Tessarolo M.;Calienni M.;Cacciotto C.;Fraboni B.;Scagliarini A.;Sambri V.
2022

Abstract

Due to the SARS-CoV-2 pandemic renewed attention has been directed towards viral neutralization assays and neutralizing antibodies quantification, for vaccine pre-clinical trials and determining vaccine efficacy over time. The gold standard to assess antibody titer is the plaque reduction neutralization test, an end-point assay which evaluates the highest serum antibody dilution that neutralizes viral replication, by inspecting the cytopathic effect induced on cell cultures. Here, we use planar, PEDOT:PSS-based organic electrochemical transistors for real-time, remote-controlled, reliable and fast electrical monitoring of the cytopathic effect induced by SARS29 CoV-2 on Vero E6 cell lines, allowing the quantification of serum neutralizing titer. Our low-cost and scalable device has the potential to speed-up large-scale viral neutralization screening without the need for cancerous staining or highly specialized operators. Finally, the technology could be easily transferred to assess neutralizing antibody response towards different viruses in their permissive cell substrates.
2022
Decataldo F., Grumiro L., Marino M.M., Faccin F., Giovannini C., Brandolini M., et al. (2022). Fast and real-time electrical transistor assay for quantifying SARS-CoV-2 neutralizing antibodies. COMMUNICATIONS MATERIALS, 3(1), 1-9 [10.1038/s43246-022-00226-6].
Decataldo F.; Grumiro L.; Marino M.M.; Faccin F.; Giovannini C.; Brandolini M.; Dirani G.; Taddei F.; Lelli D.; Tessarolo M.; Calienni M.; Cacciotto C...espandi
File in questo prodotto:
File Dimensione Formato  
s43246-022-00226-6.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 1.5 MB
Formato Adobe PDF
1.5 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/883308
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact