A new chromatographic method by Ultra High Performance Liquid Chromatographic (UHPLC) technology, has been developed and validated for the determination of polydatin and resveratrol, as potential metabolite, in human plasma. After the optimization of the chromatographic conditions, the method has been validated on spiked human plasma samples. The optimized extraction allowed to obtain analytes recovery up to 98.48 ± 4.03 %. Then, the isocratic elution in reversed phase mode, provides the separation of polydatin and resveratrol in less than 10.0 min. Chromatographic analysis was performed on a C18, 10 cm x 3.0 mm, 2.7 μm stationary phase, by using triethanolamine phosphate solution (0.1 M, pH = 3.7) and ACN 85:15 (v/v) as mobile phase at a flow rate of 0.5 mL/min. The UV detector was set at 306 nm for the analysis of both polydatin and resveratrol. The limit of detection (LoD) and the limit of quantification (LoQ) for polydatin in plasma samples were found to be 7.82 ± 0.38 nM and 26.06 ± 1.28 nM respectively. The method was found to be accurate and precise with a coefficient for intra- and inter-day variation below 5 %. All the reported data demonstrate how the developed method is rapid and sensitive. Moreover, results of the analysis of plasma samples, obtained from orally treated volunteers with nutritional supplements containing polydatin, have shown the method to be suitable for the pharmacokinetic characterization of polydatin and resveratrol, as metabolite, in humans.

Development of an UHPLC-diode arrays detector (DAD) method for the analysis of polydatin in human plasma

Montanari S.;Davani L.;Tumiatti V.;Gaddi A. V.;De Simone A.;Andrisano V.
2021

Abstract

A new chromatographic method by Ultra High Performance Liquid Chromatographic (UHPLC) technology, has been developed and validated for the determination of polydatin and resveratrol, as potential metabolite, in human plasma. After the optimization of the chromatographic conditions, the method has been validated on spiked human plasma samples. The optimized extraction allowed to obtain analytes recovery up to 98.48 ± 4.03 %. Then, the isocratic elution in reversed phase mode, provides the separation of polydatin and resveratrol in less than 10.0 min. Chromatographic analysis was performed on a C18, 10 cm x 3.0 mm, 2.7 μm stationary phase, by using triethanolamine phosphate solution (0.1 M, pH = 3.7) and ACN 85:15 (v/v) as mobile phase at a flow rate of 0.5 mL/min. The UV detector was set at 306 nm for the analysis of both polydatin and resveratrol. The limit of detection (LoD) and the limit of quantification (LoQ) for polydatin in plasma samples were found to be 7.82 ± 0.38 nM and 26.06 ± 1.28 nM respectively. The method was found to be accurate and precise with a coefficient for intra- and inter-day variation below 5 %. All the reported data demonstrate how the developed method is rapid and sensitive. Moreover, results of the analysis of plasma samples, obtained from orally treated volunteers with nutritional supplements containing polydatin, have shown the method to be suitable for the pharmacokinetic characterization of polydatin and resveratrol, as metabolite, in humans.
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Montanari S.; Davani L.; Tumiatti V.; Dimilta M.; Gaddi A.V.; De Simone A.; Andrisano V.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: http://hdl.handle.net/11585/854120
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact