In this work, Life Cycle Assessment has been applied for the evaluation of UVC-based photochemical treatments to deal with wastewater treatment plant effluents. In particular, UVC photolysis, UVC/H2O2 combination and UVC/H2O2/Fe(II) (namely photo-Fenton) were tested at pH ca. 7.5. Clostridium spp. was chosen as target species to test disinfection. Both, UVC/H2O2 and photo-Fenton were able to decrease Clostridium spp. below detection limit in 5 min. Best results were reached with H2O2 concentration of 21 mM. Coupling coagulation-flocculation with the photochemical process was tested for effluents with high organic load and turbidity. Global warming potential selected UVC photolysis as the best treatment for disinfection from the environmental point of view, despite its lower efficiency. However, when CECs removal was considered using acetaminophen as target contaminant, photo-Fenton was the most efficient and the most sustainable option. Finally, LCA was applied to the experimental work performed in the laboratory, showing that the effect of reactions was negligible vs. sample collection and transportation, as well as analytical procedures which accounted for more than 99 % of the impact.
López-Timoner, R., Santos-Juanes, L., Amat, A.M., Arfelli, F., Cespi, D., Passarini, F., et al. (2025). Life cycle assessment of UVC-based advanced oxidation processes as quaternary treatments: Clostridium spp. inactivation and comparison with CECs removal. SCIENCE OF THE TOTAL ENVIRONMENT, 972, 1-13 [10.1016/j.scitotenv.2025.179029].
Life cycle assessment of UVC-based advanced oxidation processes as quaternary treatments: Clostridium spp. inactivation and comparison with CECs removal
Arfelli, F.;Cespi, D.;Passarini, F.;
2025
Abstract
In this work, Life Cycle Assessment has been applied for the evaluation of UVC-based photochemical treatments to deal with wastewater treatment plant effluents. In particular, UVC photolysis, UVC/H2O2 combination and UVC/H2O2/Fe(II) (namely photo-Fenton) were tested at pH ca. 7.5. Clostridium spp. was chosen as target species to test disinfection. Both, UVC/H2O2 and photo-Fenton were able to decrease Clostridium spp. below detection limit in 5 min. Best results were reached with H2O2 concentration of 21 mM. Coupling coagulation-flocculation with the photochemical process was tested for effluents with high organic load and turbidity. Global warming potential selected UVC photolysis as the best treatment for disinfection from the environmental point of view, despite its lower efficiency. However, when CECs removal was considered using acetaminophen as target contaminant, photo-Fenton was the most efficient and the most sustainable option. Finally, LCA was applied to the experimental work performed in the laboratory, showing that the effect of reactions was negligible vs. sample collection and transportation, as well as analytical procedures which accounted for more than 99 % of the impact.| File | Dimensione | Formato | |
|---|---|---|---|
|
1-s2.0-S0048969725006643-main.pdf
accesso aperto
Tipo:
Versione (PDF) editoriale / Version Of Record
Licenza:
Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione
4.75 MB
Formato
Adobe PDF
|
4.75 MB | Adobe PDF | Visualizza/Apri |
|
1-s2.0-S0048969725006643-mmc1.docx
accesso aperto
Tipo:
File Supplementare
Licenza:
Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione
54.5 kB
Formato
Microsoft Word XML
|
54.5 kB | Microsoft Word XML | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.