Real-time and in-line transversal monitoring of ionizing radiation beams is a crucial task for several applications which span from medical treatments to particle accelerators in high energy physics. Here a flexible and large area device based on 2D hybrid perovskite thin films (phenylethylammonium lead bromide), fabricated onto a thin flexible polyimide substrate, able to map the transversal beam profile of high energy radiation beams is reported. The performance of this novel tool is here compared with the one offered by standard commercial large-area technology, namely radiochromic sheets. The great potential of this class of devices is demonstrated by successfully mapping in real-time a 5 MeV proton beam at fluxes between 10 8 and 10 10 H+ s−1 cm−2 , confirming the capability to operate in a radiation-harsh environment without output signal saturation issues. The versatility and scalability of here proposed detecting system are demonstrated by the development of a multipixel array able to map in real-time a 40 kVp X-ray beam spot (dose rate 8 mGy s−1 ). Perovskite thin film-based detectors are thus assessed as a very promising class of thin, flexible devices for real-time, in-line, large-area, conformable, reusable, transparent, and low-cost transversal beam monitoring of different ionizing radiation.

Fratelli, I., Basiricò, L., Ciavatti, A., Margotti, L., Cepić, S., Chiari, M., et al. (2024). Real‐Time Radiation Beam Monitoring by Flexible Perovskite Thin Film Arrays. ADVANCED SCIENCE, 2401124, 1-9 [10.1002/advs.202401124].

Real‐Time Radiation Beam Monitoring by Flexible Perovskite Thin Film Arrays

Fratelli, Ilaria;Basiricò, Laura
;
Ciavatti, Andrea;Margotti, Lorenzo;Cepić, Sara;Fraboni, Beatrice
2024

Abstract

Real-time and in-line transversal monitoring of ionizing radiation beams is a crucial task for several applications which span from medical treatments to particle accelerators in high energy physics. Here a flexible and large area device based on 2D hybrid perovskite thin films (phenylethylammonium lead bromide), fabricated onto a thin flexible polyimide substrate, able to map the transversal beam profile of high energy radiation beams is reported. The performance of this novel tool is here compared with the one offered by standard commercial large-area technology, namely radiochromic sheets. The great potential of this class of devices is demonstrated by successfully mapping in real-time a 5 MeV proton beam at fluxes between 10 8 and 10 10 H+ s−1 cm−2 , confirming the capability to operate in a radiation-harsh environment without output signal saturation issues. The versatility and scalability of here proposed detecting system are demonstrated by the development of a multipixel array able to map in real-time a 40 kVp X-ray beam spot (dose rate 8 mGy s−1 ). Perovskite thin film-based detectors are thus assessed as a very promising class of thin, flexible devices for real-time, in-line, large-area, conformable, reusable, transparent, and low-cost transversal beam monitoring of different ionizing radiation.
2024
Fratelli, I., Basiricò, L., Ciavatti, A., Margotti, L., Cepić, S., Chiari, M., et al. (2024). Real‐Time Radiation Beam Monitoring by Flexible Perovskite Thin Film Arrays. ADVANCED SCIENCE, 2401124, 1-9 [10.1002/advs.202401124].
Fratelli, Ilaria; Basiricò, Laura; Ciavatti, Andrea; Margotti, Lorenzo; Cepić, Sara; Chiari, Massimo; Fraboni, Beatrice
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/982701
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact