Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
CRIS Current Research Information System
SND@LHC is a compact and stand-alone experiment designed to perform measurements with neutrinos produced at the LHC in the pseudo-rapidity region of 7.2 < η < 8.4. The experiment is located 480 m downstream of the ATLAS interaction point, in the TI18 tunnel. The detector is composed of a hybrid system based on an 830 kg target made of tungsten plates, interleaved with emulsion and electronic trackers, also acting as an electromagnetic calorimeter, and followed by a hadronic calorimeter and a muon identification system. The detector is able to distinguish interactions of all three neutrino flavours, which allows probing the physics of heavy flavour production at the LHC in the very forward region. This region is of particular interest for future circular colliders and for very high energy astrophysical neutrino experiments. The detector is also able to search for the scattering of Feebly Interacting Particles. In its first phase, the detector is ready to operate throughout LHC Run 3 and collect a total of 250 fb−1.
Acampora G., Ahdida C., Albanese R., Albrecht C., Alexandrov A., Andreini M., et al. (2024). SND@LHC: the scattering and neutrino detector at the LHC. JOURNAL OF INSTRUMENTATION, 19(5), 1-53 [10.1088/1748-0221/19/05/P05067].
SND@LHC: the scattering and neutrino detector at the LHC
Acampora G.;Ahdida C.;Albanese R.;Albrecht C.;Alexandrov A.;Andreini M.;Anokhina A.;Asada T.;Auberson N.;Baldanza C.;Battilana C.;Bay A.;Bernard F.;Bestmann P.;Betancourt C.;Blanco A.;Bogomilov M.;Bonacorsi D.;Bonivento W. M.;Bordalo P.;Boyarsky A.;Breglio G.;Buonaura A.;Buontempo S.;Cafaro V. D.;Callignon M.;Camporesi T.;Campanelli M.;Canale V.;Cassese P.;Castro A.;Centanni D.;Godoy S. A. C.;Cerutti F.;Charitonidis N.;Chernyavskiy M.;Choi K. -Y.;Cholak S.;Cicero V.;Cindolo F.;Climescu M.;Conaboy A. P.;Congedo L.;Crespo O.;Cristinziani M.;Crupano A.;Dallavalle G. M.;D'Ambrosio N.;De Carvalho Saraiva J.;De Bryas Dexmiers D'Archiac P. T.;De Lellis G.;de Magistris M.;De Roeck A.;De Rujula A.;De Serio M.;De Simone D.;Dedenko L.;Di Crescenzo A.;Di Giulio L.;Dolmatov A.;Dreyfus L.;Durhan O.;Fabbri F.;Fasanella D.;Fedotovs F.;Ferrillo M.;Ferro-Luzzi M.;Fienga F.;Fini R. A.;Fiorillo A.;Fonte P.;Fresa R.;Frei R.;Funk W.;Galati G.;Galkin V.;Walls F. G.;Alia R. G.;Gerbershagen A.;Giordano V.;Golovatiuk A.;Golutvin A.;Gorshenkov M.;Graverini E.;Grenard J. -L.;Guler A. M.;Gulyaeva V.;Haefeli G. J.;Helo J. C.;van Herwijnen E.;Iengo P.;Ilieva S.;Infantino A.;Irace A.;Iuliano A.;Jacobsson R.;Jacquart M.;Kamiscioglu C.;Khalikov E.;Kim S. H.;Kim Y. G.;Komatsu M.;Konovalova N.;Kovalenko S.;Krasilnikova I.;Kuleshov S.;Lacker H. M.;Lantwin O.;Manghi F. L.;Lauria A.;Lee K. S.;Lee K. Y.;Leonardo N.;Vargas M. P. L.;Meo S. L.;Lemettais C.;Loschiavo V. P.;Lopes L.;Lussi B.;Marcellini S.;Margiotta A.;Magnan A.;Maier R.;Maietta M.;Malinin A.;Marrazzo V. R.;Maurer Y.;Managadze A. K.;Mascellani A.;Miano A.;Mikulenko A.;Minelli F.;Montanari A.;Montesi M. C.;Naka T.;Navarria F. L.;Ogawa S.;Okateva N.;Owtscharenko N.;Ovchynnikov M.;Park B. D.;Passeggio G.;Pastore A.;Patel M.;Patrizii L.;Perrotta A.;Petrov A.;Podgrudkov D.;Polini A.;Polukhina N.;Prota A.;Queiroz F.;Quercia A.;Ramos S.;Ratnikov F.;Reghunath A.;Riccio M.;Cavalcante A. B. R.;Roganova T.;Rovelli T.;Ruchayskiy O.;Ruf T.;Gilarte M. S.;Galan F. S.;Diaz P. S.;Schaffner M.;Schneider O.;Sekhniaidze G.;Serra N.;Shchedrina T.;Shchutska L.;Shevchenko V.;Shibuya H.;Shirobokov S.;Shmanin E.;Simone S.;Siroli G. P.;Sito L.;Sirri G.;Schmidt J.;Soares G.;Sohn J. Y.;Sandoval O. J. S.;Spurio M.;Starkov N.;Tastet J. L.;Timiryasov I.;Tioukov V.;Tosi N.;Trippl C.;Poblete P. A. U.;Ursov E.;Ustyuzhanin A.;Vankova-Kirilova G.;Vendeuvre C.;Visone C.;Vollhardt A.;Wanke R.;Yoon C. S.;Saa J. Z.;Zaffaroni E.;Zick H. J.
2024
Abstract
SND@LHC is a compact and stand-alone experiment designed to perform measurements with neutrinos produced at the LHC in the pseudo-rapidity region of 7.2 < η < 8.4. The experiment is located 480 m downstream of the ATLAS interaction point, in the TI18 tunnel. The detector is composed of a hybrid system based on an 830 kg target made of tungsten plates, interleaved with emulsion and electronic trackers, also acting as an electromagnetic calorimeter, and followed by a hadronic calorimeter and a muon identification system. The detector is able to distinguish interactions of all three neutrino flavours, which allows probing the physics of heavy flavour production at the LHC in the very forward region. This region is of particular interest for future circular colliders and for very high energy astrophysical neutrino experiments. The detector is also able to search for the scattering of Feebly Interacting Particles. In its first phase, the detector is ready to operate throughout LHC Run 3 and collect a total of 250 fb−1.
Acampora G., Ahdida C., Albanese R., Albrecht C., Alexandrov A., Andreini M., et al. (2024). SND@LHC: the scattering and neutrino detector at the LHC. JOURNAL OF INSTRUMENTATION, 19(5), 1-53 [10.1088/1748-0221/19/05/P05067].
Acampora G.; Ahdida C.; Albanese R.; Albrecht C.; Alexandrov A.; Andreini M.; Anokhina A.; Asada T.; Auberson N.; Baldanza C.; Battilana C.; Bay A.; B...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/973024
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
0
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.