Portable infrared-based instruments have made significant contributions in different research fields. Within the dairy supply chain, for example, most of portable devices are based on near-infrared spectroscopy (NIRS) and are nowadays an important support for farmers and operators of the dairy sector, allowing fast decision-making, particularly for feed and milk quality evaluation and animal health and welfare monitoring. The affordability, portability, and ease of use of these innovative devices have been pivotal factors for the implementation in dairy farms. In fact, pocket-sized devices enable non-expert users to perform quick, low cost and non-destructive analysis on various samples without complex preparation. As bovine colostrum (BC) quality is mostly given by the Ig G (IgG) level, evaluating the ability of portable NIRS tools to measure antibodies concentration is advisable. In this study we used the wireless device SCiO manufactured by Consumer Physics Inc. (Tel Aviv, Israel) to collect BC spectra and then attempt to predict IgG concentration and gross and fine composition in individual samples collected as soon as possible after calving (<6 h) in primiparous and pluriparous Holstein cows farmed in 9 Italian farms. Chemometric analyses revealed that SCiO has promising predictive performance for colostral IgG concentration, total Ig concentration, fat, and AA (R2CV ≥ 0.75). Excellent accuracy was observed for dry matter, protein, and S prediction in cross-validation and good prediction ability in external validation (R2CV ≥ 0.93; R2V ≥ 0.82). Nonetheless, SCiO's ability to discriminate between good- and low-quality samples was satisfactory. The affordable cost, the accurate predictions, and the user-friendly design coupled with the increased interest in colostrum quality within the dairy sector may boost the collection of extensive BC data for management and genetic purposes in the near future.

Goi, A., Costa, A., De Marchi, M. (2024). The ability of a handheld near-infrared spectrometer for a rapid quality assessment of bovine colostrum including the Ig G concentration. JOURNAL OF DAIRY SCIENCE, 107(7), 4344-4356 [10.3168/jds.2023-24005].

The ability of a handheld near-infrared spectrometer for a rapid quality assessment of bovine colostrum including the Ig G concentration

Costa, Angela
Conceptualization
;
2024

Abstract

Portable infrared-based instruments have made significant contributions in different research fields. Within the dairy supply chain, for example, most of portable devices are based on near-infrared spectroscopy (NIRS) and are nowadays an important support for farmers and operators of the dairy sector, allowing fast decision-making, particularly for feed and milk quality evaluation and animal health and welfare monitoring. The affordability, portability, and ease of use of these innovative devices have been pivotal factors for the implementation in dairy farms. In fact, pocket-sized devices enable non-expert users to perform quick, low cost and non-destructive analysis on various samples without complex preparation. As bovine colostrum (BC) quality is mostly given by the Ig G (IgG) level, evaluating the ability of portable NIRS tools to measure antibodies concentration is advisable. In this study we used the wireless device SCiO manufactured by Consumer Physics Inc. (Tel Aviv, Israel) to collect BC spectra and then attempt to predict IgG concentration and gross and fine composition in individual samples collected as soon as possible after calving (<6 h) in primiparous and pluriparous Holstein cows farmed in 9 Italian farms. Chemometric analyses revealed that SCiO has promising predictive performance for colostral IgG concentration, total Ig concentration, fat, and AA (R2CV ≥ 0.75). Excellent accuracy was observed for dry matter, protein, and S prediction in cross-validation and good prediction ability in external validation (R2CV ≥ 0.93; R2V ≥ 0.82). Nonetheless, SCiO's ability to discriminate between good- and low-quality samples was satisfactory. The affordable cost, the accurate predictions, and the user-friendly design coupled with the increased interest in colostrum quality within the dairy sector may boost the collection of extensive BC data for management and genetic purposes in the near future.
2024
Goi, A., Costa, A., De Marchi, M. (2024). The ability of a handheld near-infrared spectrometer for a rapid quality assessment of bovine colostrum including the Ig G concentration. JOURNAL OF DAIRY SCIENCE, 107(7), 4344-4356 [10.3168/jds.2023-24005].
Goi, Arianna; Costa, Angela; De Marchi, Massimo
File in questo prodotto:
File Dimensione Formato  
Goi et al 1-s2.0-S0022030224004934-main.pdf

accesso aperto

Descrizione: PDF online, uncorrected proof
Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 782.65 kB
Formato Adobe PDF
782.65 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/961581
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact