Background: Long-term outcomes of patients treated with helmet noninvasive ventilation (NIV) are unknown: safety concerns regarding the risk of patient self-inflicted lung injury and delayed intubation exist when NIV is applied in hypoxemic patients. We assessed the 6-month outcome of patients who received helmet NIV or high-flow nasal oxygen for COVID-19 hypoxemic respiratory failure. Methods: In this prespecified analysis of a randomized trial of helmet NIV versus high-flow nasal oxygen (HENIVOT), clinical status, physical performance (6-min-walking-test and 30-s chair stand test), respiratory function and quality of life (EuroQoL five dimensions five levels questionnaire, EuroQoL VAS, SF36 and Post-Traumatic Stress Disorder Checklist for the DSM) were evaluated 6 months after the enrollment. Results: Among 80 patients who were alive, 71 (89%) completed the follow-up: 35 had received helmet NIV, 36 high-flow oxygen. There was no inter-group difference in any item concerning vital signs (N = 4), physical performance (N = 18), respiratory function (N = 27), quality of life (N = 21) and laboratory tests (N = 15). Arthralgia was significantly lower in the helmet group (16% vs. 55%, p = 0.002). Fifty-two percent of patients in helmet group vs. 63% of patients in high-flow group had diffusing capacity of the lungs for carbon monoxide < 80% of predicted (p = 0.44); 13% vs. 22% had forced vital capacity < 80% of predicted (p = 0.51). Both groups reported similar degree of pain (p = 0.81) and anxiety (p = 0.81) at the EQ-5D-5L test; the EQ-VAS score was similar in the two groups (p = 0.27). Compared to patients who successfully avoided invasive mechanical ventilation (54/71, 76%), intubated patients (17/71, 24%) had significantly worse pulmonary function (median diffusing capacity of the lungs for carbon monoxide 66% [Interquartile range: 47–77] of predicted vs. 80% [71–88], p = 0.005) and decreased quality of life (EQ-VAS: 70 [53–70] vs. 80 [70–83], p = 0.01). Conclusions: In patients with COVID-19 hypoxemic respiratory failure, treatment with helmet NIV or high-flow oxygen yielded similar quality of life and functional outcome at 6 months. The need for invasive mechanical ventilation was associated with worse outcomes. These data indicate that helmet NIV, as applied in the HENIVOT trial, can be safely used in hypoxemic patients. Trial registration Registered on clinicaltrials.gov NCT04502576 on August 6, 2020

Long-term outcome of COVID-19 patients treated with helmet noninvasive ventilation vs. high-flow nasal oxygen: a randomized trial / Michi T.; Mattana C.; Menga L.S.; Bocci M.G.; Cesarano M.; Rosa T.; Gualano M.R.; Montomoli J.; Spadaro S.; Tosato M.; Rota E.; Landi F.; Cutuli S.L.; Tanzarella E.S.; Pintaudi G.; Piervincenzi E.; Bello G.; Tonetti T.; Rucci P.; De Pascale G.; Maggiore S.M.; Grieco D.L.; Conti G.; Antonelli M.; Maviglia R.; Mercurio G.; De Santis P.; Pennisi M.A.; Anzellotti G.M.; Torrini F.; Rubino C.; Morena T.C.; Gennenzi V.; Postorino S.; Vargas J.; Filetici N.; Settanni D.; Durante M.; Cascarano L.; Di Muro M.; Scarascia R.; Bitondo M.M.; Murdolo M.; Mele A.; Silva S.; Zaccone C.; Pozzana F.; Maccaglia A.; Savino M.; Potalivo A.; Ceccaroni F.; Scavone A.; Lombardi G.; Bello G.; Montini L.; Dell'Anna A.M.; Volta C.A.; Ranieri V.M.; Falo G.; Carelli S.; Natalini D.; Berardi C.; Delle Cese L.; Vetrugno L.; Balzani E.. - In: JOURNAL OF INTENSIVE CARE. - ISSN 2052-0492. - ELETTRONICO. - 11:1(2023), pp. 21.1-21.14. [10.1186/s40560-023-00669-0]

Long-term outcome of COVID-19 patients treated with helmet noninvasive ventilation vs. high-flow nasal oxygen: a randomized trial

Tonetti T.;Rucci P.;Ranieri V. M.;
2023

Abstract

Background: Long-term outcomes of patients treated with helmet noninvasive ventilation (NIV) are unknown: safety concerns regarding the risk of patient self-inflicted lung injury and delayed intubation exist when NIV is applied in hypoxemic patients. We assessed the 6-month outcome of patients who received helmet NIV or high-flow nasal oxygen for COVID-19 hypoxemic respiratory failure. Methods: In this prespecified analysis of a randomized trial of helmet NIV versus high-flow nasal oxygen (HENIVOT), clinical status, physical performance (6-min-walking-test and 30-s chair stand test), respiratory function and quality of life (EuroQoL five dimensions five levels questionnaire, EuroQoL VAS, SF36 and Post-Traumatic Stress Disorder Checklist for the DSM) were evaluated 6 months after the enrollment. Results: Among 80 patients who were alive, 71 (89%) completed the follow-up: 35 had received helmet NIV, 36 high-flow oxygen. There was no inter-group difference in any item concerning vital signs (N = 4), physical performance (N = 18), respiratory function (N = 27), quality of life (N = 21) and laboratory tests (N = 15). Arthralgia was significantly lower in the helmet group (16% vs. 55%, p = 0.002). Fifty-two percent of patients in helmet group vs. 63% of patients in high-flow group had diffusing capacity of the lungs for carbon monoxide < 80% of predicted (p = 0.44); 13% vs. 22% had forced vital capacity < 80% of predicted (p = 0.51). Both groups reported similar degree of pain (p = 0.81) and anxiety (p = 0.81) at the EQ-5D-5L test; the EQ-VAS score was similar in the two groups (p = 0.27). Compared to patients who successfully avoided invasive mechanical ventilation (54/71, 76%), intubated patients (17/71, 24%) had significantly worse pulmonary function (median diffusing capacity of the lungs for carbon monoxide 66% [Interquartile range: 47–77] of predicted vs. 80% [71–88], p = 0.005) and decreased quality of life (EQ-VAS: 70 [53–70] vs. 80 [70–83], p = 0.01). Conclusions: In patients with COVID-19 hypoxemic respiratory failure, treatment with helmet NIV or high-flow oxygen yielded similar quality of life and functional outcome at 6 months. The need for invasive mechanical ventilation was associated with worse outcomes. These data indicate that helmet NIV, as applied in the HENIVOT trial, can be safely used in hypoxemic patients. Trial registration Registered on clinicaltrials.gov NCT04502576 on August 6, 2020
2023
Long-term outcome of COVID-19 patients treated with helmet noninvasive ventilation vs. high-flow nasal oxygen: a randomized trial / Michi T.; Mattana C.; Menga L.S.; Bocci M.G.; Cesarano M.; Rosa T.; Gualano M.R.; Montomoli J.; Spadaro S.; Tosato M.; Rota E.; Landi F.; Cutuli S.L.; Tanzarella E.S.; Pintaudi G.; Piervincenzi E.; Bello G.; Tonetti T.; Rucci P.; De Pascale G.; Maggiore S.M.; Grieco D.L.; Conti G.; Antonelli M.; Maviglia R.; Mercurio G.; De Santis P.; Pennisi M.A.; Anzellotti G.M.; Torrini F.; Rubino C.; Morena T.C.; Gennenzi V.; Postorino S.; Vargas J.; Filetici N.; Settanni D.; Durante M.; Cascarano L.; Di Muro M.; Scarascia R.; Bitondo M.M.; Murdolo M.; Mele A.; Silva S.; Zaccone C.; Pozzana F.; Maccaglia A.; Savino M.; Potalivo A.; Ceccaroni F.; Scavone A.; Lombardi G.; Bello G.; Montini L.; Dell'Anna A.M.; Volta C.A.; Ranieri V.M.; Falo G.; Carelli S.; Natalini D.; Berardi C.; Delle Cese L.; Vetrugno L.; Balzani E.. - In: JOURNAL OF INTENSIVE CARE. - ISSN 2052-0492. - ELETTRONICO. - 11:1(2023), pp. 21.1-21.14. [10.1186/s40560-023-00669-0]
Michi T.; Mattana C.; Menga L.S.; Bocci M.G.; Cesarano M.; Rosa T.; Gualano M.R.; Montomoli J.; Spadaro S.; Tosato M.; Rota E.; Landi F.; Cutuli S.L.; Tanzarella E.S.; Pintaudi G.; Piervincenzi E.; Bello G.; Tonetti T.; Rucci P.; De Pascale G.; Maggiore S.M.; Grieco D.L.; Conti G.; Antonelli M.; Maviglia R.; Mercurio G.; De Santis P.; Pennisi M.A.; Anzellotti G.M.; Torrini F.; Rubino C.; Morena T.C.; Gennenzi V.; Postorino S.; Vargas J.; Filetici N.; Settanni D.; Durante M.; Cascarano L.; Di Muro M.; Scarascia R.; Bitondo M.M.; Murdolo M.; Mele A.; Silva S.; Zaccone C.; Pozzana F.; Maccaglia A.; Savino M.; Potalivo A.; Ceccaroni F.; Scavone A.; Lombardi G.; Bello G.; Montini L.; Dell'Anna A.M.; Volta C.A.; Ranieri V.M.; Falo G.; Carelli S.; Natalini D.; Berardi C.; Delle Cese L.; Vetrugno L.; Balzani E.
File in questo prodotto:
File Dimensione Formato  
s40560-023-00669-0.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 1.99 MB
Formato Adobe PDF
1.99 MB Adobe PDF Visualizza/Apri
file supplementari.zip

accesso aperto

Tipo: File Supplementare
Licenza: Licenza per accesso libero gratuito
Dimensione 250.96 kB
Formato Zip File
250.96 kB Zip File Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/929420
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact