High performance dampers are a key component in low-damage earthquake-resistant timber structures and they should be designed according to displacement-based design criteria. In this case, a well-defined non-linear force vs displacement relationship of the connection is to be known by the designer (e.g., to evaluate inter-storey drifts), underlying the importance of their careful experimental characterization. In this study, the cyclic shear response of a panel-to-panel joint, fastened to the wooden elements with three alternative solutions, was experimentally tested. Results showed that, although fulfilling the capacity design criteria and allowing an easy replacement of the damper, the semi-rigid nature of fastenings produces important modifications to the mechanical properties of the whole connection type, such as elastic stiffness, yielding point, ductility and equivalent viscous damping.

Role of fastenings in modifying the hysteretic response of panel-to-panel joints for CLT structures / Marchi, L; Ferretti, F; Pozza, L; Scotta, R. - In: CONSTRUCTION AND BUILDING MATERIALS. - ISSN 0950-0618. - ELETTRONICO. - 364:(2023), pp. 129856-129869. [10.1016/j.conbuildmat.2022.129856]

Role of fastenings in modifying the hysteretic response of panel-to-panel joints for CLT structures

Ferretti, F
Secondo
;
Pozza, L
Penultimo
;
2023

Abstract

High performance dampers are a key component in low-damage earthquake-resistant timber structures and they should be designed according to displacement-based design criteria. In this case, a well-defined non-linear force vs displacement relationship of the connection is to be known by the designer (e.g., to evaluate inter-storey drifts), underlying the importance of their careful experimental characterization. In this study, the cyclic shear response of a panel-to-panel joint, fastened to the wooden elements with three alternative solutions, was experimentally tested. Results showed that, although fulfilling the capacity design criteria and allowing an easy replacement of the damper, the semi-rigid nature of fastenings produces important modifications to the mechanical properties of the whole connection type, such as elastic stiffness, yielding point, ductility and equivalent viscous damping.
2023
Role of fastenings in modifying the hysteretic response of panel-to-panel joints for CLT structures / Marchi, L; Ferretti, F; Pozza, L; Scotta, R. - In: CONSTRUCTION AND BUILDING MATERIALS. - ISSN 0950-0618. - ELETTRONICO. - 364:(2023), pp. 129856-129869. [10.1016/j.conbuildmat.2022.129856]
Marchi, L; Ferretti, F; Pozza, L; Scotta, R
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/919141
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact