High performance dampers are a key component in low-damage earthquake-resistant timber structures and they should be designed according to displacement-based design criteria. In this case, a well-defined non-linear force vs displacement relationship of the connection is to be known by the designer (e.g., to evaluate inter-storey drifts), underlying the importance of their careful experimental characterization. In this study, the cyclic shear response of a panel-to-panel joint, fastened to the wooden elements with three alternative solutions, was experimentally tested. Results showed that, although fulfilling the capacity design criteria and allowing an easy replacement of the damper, the semi-rigid nature of fastenings produces important modifications to the mechanical properties of the whole connection type, such as elastic stiffness, yielding point, ductility and equivalent viscous damping.

Marchi, L., Ferretti, F., Pozza, L., Scotta, R. (2023). Role of fastenings in modifying the hysteretic response of panel-to-panel joints for CLT structures. CONSTRUCTION AND BUILDING MATERIALS, 364, 1-14 [10.1016/j.conbuildmat.2022.129856].

Role of fastenings in modifying the hysteretic response of panel-to-panel joints for CLT structures

Ferretti, F
Secondo
;
Pozza, L
Penultimo
;
2023

Abstract

High performance dampers are a key component in low-damage earthquake-resistant timber structures and they should be designed according to displacement-based design criteria. In this case, a well-defined non-linear force vs displacement relationship of the connection is to be known by the designer (e.g., to evaluate inter-storey drifts), underlying the importance of their careful experimental characterization. In this study, the cyclic shear response of a panel-to-panel joint, fastened to the wooden elements with three alternative solutions, was experimentally tested. Results showed that, although fulfilling the capacity design criteria and allowing an easy replacement of the damper, the semi-rigid nature of fastenings produces important modifications to the mechanical properties of the whole connection type, such as elastic stiffness, yielding point, ductility and equivalent viscous damping.
2023
Marchi, L., Ferretti, F., Pozza, L., Scotta, R. (2023). Role of fastenings in modifying the hysteretic response of panel-to-panel joints for CLT structures. CONSTRUCTION AND BUILDING MATERIALS, 364, 1-14 [10.1016/j.conbuildmat.2022.129856].
Marchi, L; Ferretti, F; Pozza, L; Scotta, R
File in questo prodotto:
File Dimensione Formato  
2022_Conn_innovative_Final-Revised_PrePrint.pdf

Open Access dal 08/12/2024

Tipo: Postprint
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione - Non commerciale - Non opere derivate (CCBYNCND)
Dimensione 2.19 MB
Formato Adobe PDF
2.19 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/919141
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact