This article tests the suitability of a new method to monitor the degree of substitution of cellulose acetate films, by employing a compact and inexpensive near-infrared miniaturized spectrometer (908.1–1676.2 nm) that can be easily applied in situ. The present study compares the analytical performance of the proposed method against conventional diagnostic strategies based on benchtop micro-attenuated total reflectance Fourier transform Infrared (μATR -FTIR) measurements in the mid-infrared spectral range. The novel calibration function exploits the shifts in the first overtone of the hydroxyl stretching 2νOH band of probe materials and was created using a set of analytical standards with different degrees of substitution. The robustness of the method was assessed by application on a group of sixteen historical cinematographic films. The accurate condition assessment of these films was performed in situ, in a non-invasive manner. The proposed analytical procedure is quick and easy-to-implement, and therefore it constitutes a rapid method to guide conservation strategies regarding film storage and digitalization in cultural institutions, including museums and cinematheques. Potential applications on three-dimensional objects and industrial processes are possible.

Chavez Lozano M.V., Catelli E., Sciutto G., Prati S., Genorini E., Mazzeo R. (2023). A non-invasive diagnostic tool for cellulose acetate films using a portable miniaturized near infrared spectrometer. TALANTA, 255, 1-8 [10.1016/j.talanta.2022.124223].

A non-invasive diagnostic tool for cellulose acetate films using a portable miniaturized near infrared spectrometer

Chavez Lozano M. V.;Catelli E.;Sciutto G.;Prati S.;Mazzeo R.
2023

Abstract

This article tests the suitability of a new method to monitor the degree of substitution of cellulose acetate films, by employing a compact and inexpensive near-infrared miniaturized spectrometer (908.1–1676.2 nm) that can be easily applied in situ. The present study compares the analytical performance of the proposed method against conventional diagnostic strategies based on benchtop micro-attenuated total reflectance Fourier transform Infrared (μATR -FTIR) measurements in the mid-infrared spectral range. The novel calibration function exploits the shifts in the first overtone of the hydroxyl stretching 2νOH band of probe materials and was created using a set of analytical standards with different degrees of substitution. The robustness of the method was assessed by application on a group of sixteen historical cinematographic films. The accurate condition assessment of these films was performed in situ, in a non-invasive manner. The proposed analytical procedure is quick and easy-to-implement, and therefore it constitutes a rapid method to guide conservation strategies regarding film storage and digitalization in cultural institutions, including museums and cinematheques. Potential applications on three-dimensional objects and industrial processes are possible.
2023
Chavez Lozano M.V., Catelli E., Sciutto G., Prati S., Genorini E., Mazzeo R. (2023). A non-invasive diagnostic tool for cellulose acetate films using a portable miniaturized near infrared spectrometer. TALANTA, 255, 1-8 [10.1016/j.talanta.2022.124223].
Chavez Lozano M.V.; Catelli E.; Sciutto G.; Prati S.; Genorini E.; Mazzeo R.
File in questo prodotto:
File Dimensione Formato  
915780.pdf

embargo fino al 04/01/2025

Tipo: Postprint
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione - Non commerciale - Non opere derivate (CCBYNCND)
Dimensione 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF   Visualizza/Apri   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/915780
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact