Templating plays a key role in surgery that is often underestimated. There is a difference between planning and templating: in the first not only the hip is considered but involves the evaluation of the patient in its entirety. Templating instead consists of calculating the position of the implant in order to place it in the best possible position. Fundamental is a correct X-ray of the pelvis, which must follow certain standards. For traditional templating, drawings on appropriately enlarged transparent implants were provided by the prosthesis manufacturer. The implementation of digital software into clinical practice has improved the accuracy and reproducibility of templating, which in most surgical units is performed by standard 2D radiographic images. Thanks to digital preoperative templating in a digital radiology environment, the hip reconstructive surgeon can perform preoperative planning and implant sizing quickly, consistently, and affordably. Currently, 3D templating can also be performed by software used initially to create personalized stems for THA. Aim of the current review is to outline the essentials of correct templating in THA performance, and to report the updates since the introduction of digital and 3D technologies in this setting.

How to perform correct templating in total hip replacement / Di Martino, V Rossomando, M Brunello, C D'Agostino, D Pederiva, J Frugiuele, F Pilla , C Faldini. - In: MUSCULOSKELETAL SURGERY. - ISSN 2035-5114. - ELETTRONICO. - 106:(2023), pp. 1-10. [10.1007/s12306-023-00772-3]

How to perform correct templating in total hip replacement

Di Martino;V Rossomando;M Brunello;D Pederiva;F Pilla;C Faldini
2023

Abstract

Templating plays a key role in surgery that is often underestimated. There is a difference between planning and templating: in the first not only the hip is considered but involves the evaluation of the patient in its entirety. Templating instead consists of calculating the position of the implant in order to place it in the best possible position. Fundamental is a correct X-ray of the pelvis, which must follow certain standards. For traditional templating, drawings on appropriately enlarged transparent implants were provided by the prosthesis manufacturer. The implementation of digital software into clinical practice has improved the accuracy and reproducibility of templating, which in most surgical units is performed by standard 2D radiographic images. Thanks to digital preoperative templating in a digital radiology environment, the hip reconstructive surgeon can perform preoperative planning and implant sizing quickly, consistently, and affordably. Currently, 3D templating can also be performed by software used initially to create personalized stems for THA. Aim of the current review is to outline the essentials of correct templating in THA performance, and to report the updates since the introduction of digital and 3D technologies in this setting.
2023
How to perform correct templating in total hip replacement / Di Martino, V Rossomando, M Brunello, C D'Agostino, D Pederiva, J Frugiuele, F Pilla , C Faldini. - In: MUSCULOSKELETAL SURGERY. - ISSN 2035-5114. - ELETTRONICO. - 106:(2023), pp. 1-10. [10.1007/s12306-023-00772-3]
Di Martino, V Rossomando, M Brunello, C D'Agostino, D Pederiva, J Frugiuele, F Pilla , C Faldini
File in questo prodotto:
File Dimensione Formato  
s12306-023-00772-3.pdf

accesso riservato

Tipo: Versione (PDF) editoriale
Licenza: Licenza per accesso riservato
Dimensione 1.45 MB
Formato Adobe PDF
1.45 MB Adobe PDF   Visualizza/Apri   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/914639
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? ND
social impact