The direct detection of 5-MeV protons by flexible organic detectors based on thin films is here demonstrated. The organic devices act as a solid-state detector, in which the energy released by the protons within the active layer of the sensor is converted into an electrical current. These sensors can quantitatively and reliably measure the dose of protons impinging on the sensor both in real time and in integration mode. This study shows how to detect and exploit the energy absorbed both by the organic semiconducting layer and by the plastic substrate, allowing to extrapolate information on the present and past irradiation of the detector. The measured sensitivity, S = (5.15 +/- 0.13) pC Gy(-1), and limit of detection, LOD = (30 +/- 6) cGy s(-1), of the here proposed detectors assess their efficacy and their potential as proton dosimeters in several fields of application, such as in medical proton therapy.

Direct detection of 5-MeV protons by flexible organic thin-film devices / Fratelli, Ilaria; Ciavatti, Andrea; Zanazzi, Enrico; Basiricòo' Laura; Chiari, Massimo; Fabbri, Laura; Anthony, John E; Quaranta, Alberto; Fraboni, Beatrice. - In: SCIENCE ADVANCES. - ISSN 2375-2548. - ELETTRONICO. - 7:16(2021), pp. eabf4462.1-eabf4462.7. [10.1126/sciadv.abf4462]

Direct detection of 5-MeV protons by flexible organic thin-film devices

Fratelli, Ilaria
;
Ciavatti, Andrea;Fabbri, Laura;Fraboni, Beatrice
2021

Abstract

The direct detection of 5-MeV protons by flexible organic detectors based on thin films is here demonstrated. The organic devices act as a solid-state detector, in which the energy released by the protons within the active layer of the sensor is converted into an electrical current. These sensors can quantitatively and reliably measure the dose of protons impinging on the sensor both in real time and in integration mode. This study shows how to detect and exploit the energy absorbed both by the organic semiconducting layer and by the plastic substrate, allowing to extrapolate information on the present and past irradiation of the detector. The measured sensitivity, S = (5.15 +/- 0.13) pC Gy(-1), and limit of detection, LOD = (30 +/- 6) cGy s(-1), of the here proposed detectors assess their efficacy and their potential as proton dosimeters in several fields of application, such as in medical proton therapy.
2021
Direct detection of 5-MeV protons by flexible organic thin-film devices / Fratelli, Ilaria; Ciavatti, Andrea; Zanazzi, Enrico; Basiricòo' Laura; Chiari, Massimo; Fabbri, Laura; Anthony, John E; Quaranta, Alberto; Fraboni, Beatrice. - In: SCIENCE ADVANCES. - ISSN 2375-2548. - ELETTRONICO. - 7:16(2021), pp. eabf4462.1-eabf4462.7. [10.1126/sciadv.abf4462]
Fratelli, Ilaria; Ciavatti, Andrea; Zanazzi, Enrico; Basiricòo' Laura; Chiari, Massimo; Fabbri, Laura; Anthony, John E; Quaranta, Alberto; Fraboni, Beatrice
File in questo prodotto:
File Dimensione Formato  
sciadv.abf4462.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione - Non commerciale (CCBYNC)
Dimensione 566.11 kB
Formato Adobe PDF
566.11 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/907582
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 10
social impact