Organic semiconductors are excellent candidates for X-ray detectors that can adapt to new applications, with unique properties including mechanical flexibility and the ability to cover large surfaces. Their chemical composition, primarily carbon and hydrogen, makes them human tissue equivalent in terms of radiation absorption. This is a highly desirable property for a radiation dosimeter to be employed in medical diagnostics and therapy, however a low-Z composition limits the absorption of ionizing radiation. The detection efficiency can be enhanced by considering the photoconductive gain (PG) effect, a significant contributor to the ionizing radiation detection mechanism in this class of materials. In this work, a process of controlled solution deposition by nozzle printing and crystallization of an organic semiconductor thin film is demonstrated whereby a flexible, arrayed thin-film X-ray detector with record X-ray sensitivities among flexible radiation detectors (S = (9.0 +/- 0.4) x 10(7) mu C Gy(-1) cm(-3)) is developed. The excitonic peaks responsible for the activation of the PG effect are investigated and identified using a novel technique called photocurrent spectroscopy optical quenching, and the analysis of the changes in trap states is further demonstrated.

Fratelli, I., Basirico', L., Ciavatti, A., Lamport, Z.A., Anthony, J.E., Kymissis, I., et al. (2022). Trap States Ruling Photoconductive Gain in Tissue-Equivalent, Printed Organic X-Ray Detectors. ADVANCED MATERIALS TECHNOLOGIES, 8(3), 1-10 [10.1002/admt.202200769].

Trap States Ruling Photoconductive Gain in Tissue-Equivalent, Printed Organic X-Ray Detectors

Fratelli, I;Basirico', L;Ciavatti, A;Fraboni, B
2022

Abstract

Organic semiconductors are excellent candidates for X-ray detectors that can adapt to new applications, with unique properties including mechanical flexibility and the ability to cover large surfaces. Their chemical composition, primarily carbon and hydrogen, makes them human tissue equivalent in terms of radiation absorption. This is a highly desirable property for a radiation dosimeter to be employed in medical diagnostics and therapy, however a low-Z composition limits the absorption of ionizing radiation. The detection efficiency can be enhanced by considering the photoconductive gain (PG) effect, a significant contributor to the ionizing radiation detection mechanism in this class of materials. In this work, a process of controlled solution deposition by nozzle printing and crystallization of an organic semiconductor thin film is demonstrated whereby a flexible, arrayed thin-film X-ray detector with record X-ray sensitivities among flexible radiation detectors (S = (9.0 +/- 0.4) x 10(7) mu C Gy(-1) cm(-3)) is developed. The excitonic peaks responsible for the activation of the PG effect are investigated and identified using a novel technique called photocurrent spectroscopy optical quenching, and the analysis of the changes in trap states is further demonstrated.
2022
Fratelli, I., Basirico', L., Ciavatti, A., Lamport, Z.A., Anthony, J.E., Kymissis, I., et al. (2022). Trap States Ruling Photoconductive Gain in Tissue-Equivalent, Printed Organic X-Ray Detectors. ADVANCED MATERIALS TECHNOLOGIES, 8(3), 1-10 [10.1002/admt.202200769].
Fratelli, I; Basirico', L; Ciavatti, A; Lamport, ZA; Anthony, JE; Kymissis, I; Fraboni, B
File in questo prodotto:
File Dimensione Formato  
Adv Materials Technologies - 2022 - Fratelli - Trap States Ruling Photoconductive Gain in Tissue‐Equivalent Printed.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 1.65 MB
Formato Adobe PDF
1.65 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/907550
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact