This work aims to describe the development and validation of two low-intensity pulsed ultrasound stimulation systems able to control the dose delivered to the biological target. Transducer characterization was performed in terms of pressure field shape and intensity, for a high-frequency range (500 kHz to 5 MHz) and for a low- frequency value (38 kHz). This allowed defining the distance, on the beam axis, at which biological samples should be placed during stimulation and to exactly know the intensity at the target. Carefully designed retaining systems were developed, for hosting biological samples. Sealing tests proved their impermeability to external contaminants. The assembly/de-assembly time of the systems resulted ~3 min. Time-domain acoustic simula- tions allowed to precisely estimate the ultrasound beam within the biological sample chamber, thus enabling the possibility to precisely control the pressure to be transmitted to the biological target, by modulating the trans- ducer’s input voltage. Biological in vitro tests were also carried out, demonstrating the sterility of the system and the absence of toxic and inflammatory effects on growing cells after multiple immersions in water, over seven days

Development and validation of low-intensity pulsed ultrasound systems for highly controlled in vitro cell stimulation / Fontana, F; Iberite, F; Cafarelli, A; Aliperta, A; Baldi, G; Gabusi, E; Dolzani, P; Cristino, S; Lisignoli, G; Pratellesi, T; Dumont, E; Ricotti, L. - In: ULTRASONICS. - ISSN 1874-9968. - ELETTRONICO. - 116:(2021), pp. 106495.1-106495.12. [10.1016/j.ultras.2021.106495]

Development and validation of low-intensity pulsed ultrasound systems for highly controlled in vitro cell stimulation

Fontana, F;Gabusi, E;Dolzani, P;Cristino, S;
2021

Abstract

This work aims to describe the development and validation of two low-intensity pulsed ultrasound stimulation systems able to control the dose delivered to the biological target. Transducer characterization was performed in terms of pressure field shape and intensity, for a high-frequency range (500 kHz to 5 MHz) and for a low- frequency value (38 kHz). This allowed defining the distance, on the beam axis, at which biological samples should be placed during stimulation and to exactly know the intensity at the target. Carefully designed retaining systems were developed, for hosting biological samples. Sealing tests proved their impermeability to external contaminants. The assembly/de-assembly time of the systems resulted ~3 min. Time-domain acoustic simula- tions allowed to precisely estimate the ultrasound beam within the biological sample chamber, thus enabling the possibility to precisely control the pressure to be transmitted to the biological target, by modulating the trans- ducer’s input voltage. Biological in vitro tests were also carried out, demonstrating the sterility of the system and the absence of toxic and inflammatory effects on growing cells after multiple immersions in water, over seven days
2021
Development and validation of low-intensity pulsed ultrasound systems for highly controlled in vitro cell stimulation / Fontana, F; Iberite, F; Cafarelli, A; Aliperta, A; Baldi, G; Gabusi, E; Dolzani, P; Cristino, S; Lisignoli, G; Pratellesi, T; Dumont, E; Ricotti, L. - In: ULTRASONICS. - ISSN 1874-9968. - ELETTRONICO. - 116:(2021), pp. 106495.1-106495.12. [10.1016/j.ultras.2021.106495]
Fontana, F; Iberite, F; Cafarelli, A; Aliperta, A; Baldi, G; Gabusi, E; Dolzani, P; Cristino, S; Lisignoli, G; Pratellesi, T; Dumont, E; Ricotti, L
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0041624X21001268-main (1).pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione - Non commerciale - Non opere derivate (CCBYNCND)
Dimensione 784.65 kB
Formato Adobe PDF
784.65 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/849642
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 17
social impact