Thirteen healthy Labrador retrievers underwent a 5-stage incremental treadmill exercise test to assess its reliability. Blood lactate (BL), heart rate (HR), and body temperature (BT) were measured at rest, after each stage of exercise, and after a 20-min recovery. Reproducibility was assessed by repeating the test after 7 days. Two-way MANOVAs revealed significant differences between consecutive stages, and between values at rest and after recovery. There was also a significant reduction in physiological strain between the first and second trial (learning effect). Test reliability expressed as typical error (BL = 0.22 mmol/l, HR = 9.81 bpm, BT = 0.22°C), coefficient of variation (BL = 19.3%, HR = 7.9% and BT = 0.6%) and test-retest correlation (BL = 0.89, HR = 0.96, BT = 0.95) was good. Results support test reproducibility although the learning effect needs to be controlled when investigating the exercise-related problems commonly observed in this breed. © Springer-Verlag 2009.
Ferasin, L., Marcora, S. (2009). Reliability of an incremental exercise test to evaluate acute blood lactate, heart rate and body temperature responses in Labrador retrievers. JOURNAL OF COMPARATIVE PHYSIOLOGY. B, BIOCHEMICAL, SYSTEMIC, AND ENVIRONMENTAL PHYSIOLOGY, 179(7), 839-845 [10.1007/s00360-009-0367-z].
Reliability of an incremental exercise test to evaluate acute blood lactate, heart rate and body temperature responses in Labrador retrievers
Marcora, S.
2009
Abstract
Thirteen healthy Labrador retrievers underwent a 5-stage incremental treadmill exercise test to assess its reliability. Blood lactate (BL), heart rate (HR), and body temperature (BT) were measured at rest, after each stage of exercise, and after a 20-min recovery. Reproducibility was assessed by repeating the test after 7 days. Two-way MANOVAs revealed significant differences between consecutive stages, and between values at rest and after recovery. There was also a significant reduction in physiological strain between the first and second trial (learning effect). Test reliability expressed as typical error (BL = 0.22 mmol/l, HR = 9.81 bpm, BT = 0.22°C), coefficient of variation (BL = 19.3%, HR = 7.9% and BT = 0.6%) and test-retest correlation (BL = 0.89, HR = 0.96, BT = 0.95) was good. Results support test reproducibility although the learning effect needs to be controlled when investigating the exercise-related problems commonly observed in this breed. © Springer-Verlag 2009.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.