Promotion of retrofit actions on existing buildings is a goal in Italy, since most of them were built before the 80s when little attention was paid to energy saving. This paper presents an integrated passive design approach to reduce the heating demand and limit the costs of a representative existing residential complex located in Bologna, in the northern part of Italy. To this purpose, we explored different scenarios upon actions taken on the building structure: (1) High efficiency windows; (2) additional insulation on the external walls; or (3) the simultaneous application of high efficiency windows and improved thermal envelope, on both external walls and roofing. The numerical optimization has been performed dynamically using TRNSYS simulation tool, to evaluate energy consumptions in different structural conditions. Then, the developed model has been calibrated by the real consumption data deduced from energy bills (years 2009-2015). Finally, the energy results obtained in the above mentioned different scenarios have been evaluated under an economic assessment of cost investment: It has been highlighted that the payback time (PBT) results to be strongly influenced by the national policies of fiscal incentives. According to the present model, the most profitable condition is obtained when additional insulation on the external walls is applied: The total amount of energy saving resulted to be equal to 930.4 MWh, with an optimal PBT of roughly six years, when tax refund was contemplated.
Biserni, C., Valdiserri, P., D'Orazio, D., Garai, M. (2018). Energy retrofitting strategies and economic assessments: The case study of a residential complex using utility bills. ENERGIES, 11(8), 1-15 [10.3390/en11082055].
Energy retrofitting strategies and economic assessments: The case study of a residential complex using utility bills
Biserni, Cesare;Valdiserri, Paolo;D'Orazio, Dario
;Garai, Massimo
2018
Abstract
Promotion of retrofit actions on existing buildings is a goal in Italy, since most of them were built before the 80s when little attention was paid to energy saving. This paper presents an integrated passive design approach to reduce the heating demand and limit the costs of a representative existing residential complex located in Bologna, in the northern part of Italy. To this purpose, we explored different scenarios upon actions taken on the building structure: (1) High efficiency windows; (2) additional insulation on the external walls; or (3) the simultaneous application of high efficiency windows and improved thermal envelope, on both external walls and roofing. The numerical optimization has been performed dynamically using TRNSYS simulation tool, to evaluate energy consumptions in different structural conditions. Then, the developed model has been calibrated by the real consumption data deduced from energy bills (years 2009-2015). Finally, the energy results obtained in the above mentioned different scenarios have been evaluated under an economic assessment of cost investment: It has been highlighted that the payback time (PBT) results to be strongly influenced by the national policies of fiscal incentives. According to the present model, the most profitable condition is obtained when additional insulation on the external walls is applied: The total amount of energy saving resulted to be equal to 930.4 MWh, with an optimal PBT of roughly six years, when tax refund was contemplated.File | Dimensione | Formato | |
---|---|---|---|
Biserni et al 2018 energies-11-02055.pdf
accesso aperto
Descrizione: PDF editoriale
Tipo:
Versione (PDF) editoriale
Licenza:
Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione
1.82 MB
Formato
Adobe PDF
|
1.82 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.