BACKGROUND AND PURPOSE: T2-weighted FLAIR can be combined with 3D-FSE sequences with isotropic voxels, yielding higher signal-Tonoise ratio than 2D-FLAIR. Our aim was to explore whether a T2-weighted FLAIR-volume isotropic turbo spin-echo acquisition sequence (FLAIR-VISTA) with fat suppression shows areas of abnormal brain T2 hyperintensities with better conspicuity in children than a single 2D-FLAIR sequence. MATERIALS AND METHODS: One week after a joint training session with 20 3TMRimaging examinations (8 under sedation), 3 radiologists independently evaluated the presence and conspicuity of abnormal areas of T2 hyperintensities of the brain in FLAIR-VISTA with fat suppression (sagittal source and axial and coronal reformatted images) and in axial 2D-FLAIR without fat suppression in a test set of 100 3T MR imaging examinations (34 under sedation) of patients 2-18 years of age performed for several clinical indications. Their agreement was measured with weighted κ statistics. RESULTS: Agreement was "substantial" (mean, 0.61 for 3 observers; range, 0.49 - 0.69 for observer pairs) for the presence of abnormal T2 hyperintensities and "fair" (mean, 0.29; range, 0.23- 0.38) for the comparative evaluation of lesion conspicuity. In 21 of 23 examinations in which the 3 radiologists agreed on the presence of abnormal T2 hyperintensities, FLAIR-VISTA with fat suppression images were judged to show hyperintensities with better conspicuity than 2D-FLAIR. In 2 cases, conspicuity was equal, and in no case was conspicuity better in 2D-FLAIR. CONCLUSIONS: FLAIR-VISTA with fat suppression can replace the 2D-FLAIR sequence in brain MR imaging protocols for children.
Mascalchi, M., Bianchi, A., Basile, M., Gulino, P., Trifan, M., Difeo, D., et al. (2016). Effectiveness of 3D T2-weighted FLAIR FSE sequences with fat suppression for detection of brain mr imaging signal changes in children. AJNR, AMERICAN JOURNAL OF NEURORADIOLOGY, 37(12), 2376-2381 [10.3174/ajnr.A4915].
Effectiveness of 3D T2-weighted FLAIR FSE sequences with fat suppression for detection of brain mr imaging signal changes in children
DICIOTTI, STEFANO
2016
Abstract
BACKGROUND AND PURPOSE: T2-weighted FLAIR can be combined with 3D-FSE sequences with isotropic voxels, yielding higher signal-Tonoise ratio than 2D-FLAIR. Our aim was to explore whether a T2-weighted FLAIR-volume isotropic turbo spin-echo acquisition sequence (FLAIR-VISTA) with fat suppression shows areas of abnormal brain T2 hyperintensities with better conspicuity in children than a single 2D-FLAIR sequence. MATERIALS AND METHODS: One week after a joint training session with 20 3TMRimaging examinations (8 under sedation), 3 radiologists independently evaluated the presence and conspicuity of abnormal areas of T2 hyperintensities of the brain in FLAIR-VISTA with fat suppression (sagittal source and axial and coronal reformatted images) and in axial 2D-FLAIR without fat suppression in a test set of 100 3T MR imaging examinations (34 under sedation) of patients 2-18 years of age performed for several clinical indications. Their agreement was measured with weighted κ statistics. RESULTS: Agreement was "substantial" (mean, 0.61 for 3 observers; range, 0.49 - 0.69 for observer pairs) for the presence of abnormal T2 hyperintensities and "fair" (mean, 0.29; range, 0.23- 0.38) for the comparative evaluation of lesion conspicuity. In 21 of 23 examinations in which the 3 radiologists agreed on the presence of abnormal T2 hyperintensities, FLAIR-VISTA with fat suppression images were judged to show hyperintensities with better conspicuity than 2D-FLAIR. In 2 cases, conspicuity was equal, and in no case was conspicuity better in 2D-FLAIR. CONCLUSIONS: FLAIR-VISTA with fat suppression can replace the 2D-FLAIR sequence in brain MR imaging protocols for children.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.