NMR relaxation time distributions, obtained with laboratory and portable devices, are utilized to characterize the pore-size distributions of building materials coming from the Roman remains of the Greek-Roman Theatre of Taormina. To validate the interpretation of relaxation data in terms of pore-size distribution, comparison of results from standard and in situ NMR experiments with results of the mercury intrusion porosimetry (MIP) has been made. Although the pore-size distributions can be obtained by NMR in terms of either longitudinal (T1) or transverse (T2) relaxation times distributions, the shorter duration of the T2 measurement makes it, in principle, preferable, although the determination of T2 distributions is not necessarily an easy alternative to finding T1 distributions. Among other things, the T1 distribution is almost independent of the inhomogeneity of the magnetic field, while the T2 distribution is strongly influenced by it. This paper was aimed at answering two questions: what are the validity limits to interpret NMR data in terms of pore-size distributions and whether the portable device can successfully be applied as a non-destructive and non-invasive tool for in situ NMR analysis of building materials, particularly those of Cultural Heritage interest.

M. Brai, C. Casieri, F. De Luca, P. Fantazzini, M. Gombia, C. Terenzi (2007). Validity of NMR pore-size analysis of cultutal heritage ancient building materials containing magnetic impurities. SOLID STATE NUCLEAR MAGNETIC RESONANCE, 32, 129-135 [10.1016/j.ssnmr.2007.10.005].

Validity of NMR pore-size analysis of cultutal heritage ancient building materials containing magnetic impurities

FANTAZZINI, PAOLA;GOMBIA, MIRKO;
2007

Abstract

NMR relaxation time distributions, obtained with laboratory and portable devices, are utilized to characterize the pore-size distributions of building materials coming from the Roman remains of the Greek-Roman Theatre of Taormina. To validate the interpretation of relaxation data in terms of pore-size distribution, comparison of results from standard and in situ NMR experiments with results of the mercury intrusion porosimetry (MIP) has been made. Although the pore-size distributions can be obtained by NMR in terms of either longitudinal (T1) or transverse (T2) relaxation times distributions, the shorter duration of the T2 measurement makes it, in principle, preferable, although the determination of T2 distributions is not necessarily an easy alternative to finding T1 distributions. Among other things, the T1 distribution is almost independent of the inhomogeneity of the magnetic field, while the T2 distribution is strongly influenced by it. This paper was aimed at answering two questions: what are the validity limits to interpret NMR data in terms of pore-size distributions and whether the portable device can successfully be applied as a non-destructive and non-invasive tool for in situ NMR analysis of building materials, particularly those of Cultural Heritage interest.
2007
M. Brai, C. Casieri, F. De Luca, P. Fantazzini, M. Gombia, C. Terenzi (2007). Validity of NMR pore-size analysis of cultutal heritage ancient building materials containing magnetic impurities. SOLID STATE NUCLEAR MAGNETIC RESONANCE, 32, 129-135 [10.1016/j.ssnmr.2007.10.005].
M. Brai; C. Casieri; F. De Luca; P. Fantazzini; M. Gombia; C. Terenzi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/55514
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 22
social impact