The evaluation of the knee joint behavior is fundamental in many applications, such as joint modeling, prosthesis and orthosis design. A new test rig for in vitro analysis of the knee joint behavior is presented in this paper. Based on a cable-driven parallel manipulator loading system, the rig can simulate general loading conditions, such as clinical tests and common daily activities, in a wide range of flexion angles. The joint natural response in terms of movement is measured by an optoelectronic system. Furthermore, the new rig allows the estimation of the contribution of the principal leg muscles in guaranteeing the equilibrium of the joint. Despite its simplicity and low cost, the rig presents good accuracy, repeatability and versatility that allow its application on a wide range of specimen sizes. It represents an advanced application of cable-driven parallel robots for in vitro motion analysis of the knee subjected to general loads.

A new test rig for static and dynamic evaluation of knee motion based on a cable-driven parallel manipulator loading system

SANCISI, NICOLA;CONCONI, MICHELE;PARENTI CASTELLI, VINCENZO
2016

Abstract

The evaluation of the knee joint behavior is fundamental in many applications, such as joint modeling, prosthesis and orthosis design. A new test rig for in vitro analysis of the knee joint behavior is presented in this paper. Based on a cable-driven parallel manipulator loading system, the rig can simulate general loading conditions, such as clinical tests and common daily activities, in a wide range of flexion angles. The joint natural response in terms of movement is measured by an optoelectronic system. Furthermore, the new rig allows the estimation of the contribution of the principal leg muscles in guaranteeing the equilibrium of the joint. Despite its simplicity and low cost, the rig presents good accuracy, repeatability and versatility that allow its application on a wide range of specimen sizes. It represents an advanced application of cable-driven parallel robots for in vitro motion analysis of the knee subjected to general loads.
2016
Forlani, Margherita; Sancisi, Nicola; Conconi, Michele; Parenti-Castelli, Vincenzo
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/552412
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 11
social impact