The semiconductor tracker is a silicon microstrip detector forming part of the inner tracking system of the ATLAS experiment at the LHC. The operation and performance of the semiconductor tracker during the first years of LHC running are described. More than 99% of the detector modules were operational during this period, with an average intrinsic hit efficiency of (99.74±0.04)%. The evolution of the noise occupancy is discussed, and measurements of the Lorentz angle, d-ray production and energy loss presented. The alignment of the detector is found to be stable at the few-micron level over long periods of time. Radiation damage measurements, which include the evolution of detector leakage currents, are found to be consistent with predictions and are used in the verification of radiation background simulations.

The ATLAS collaboration: Aad, G., Abbott, B., Abdallah, J., Abdel Khalek, S., Abdinov, O., Aben, R., et al. (2014). Operation and performance of the ATLAS semiconductor tracker. JOURNAL OF INSTRUMENTATION, 9(8), P08009-1-P08009-74 [10.1088/1748-0221/9/08/P08009].

Operation and performance of the ATLAS semiconductor tracker

ALBERGHI, GIAN LUIGI;BELLAGAMBA, LORENZO;BOSCHERINI, DAVIDE;BRUNI, ALESSIA;BRUNI, GRAZIANO;DE CASTRO, STEFANO;FABBRI, LAURA;FRANCHINI, MATTEO;GABRIELLI, ALESSANDRO;GIACOBBE, BENEDETTO;MASSA, IGNAZIO GIACOMO;MENGARELLI, ALBERTO;POLINI, ALESSANDRO;RINALDI, LORENZO;ROMANO, MARINO;SBARRA, CARLA;SEMPRINI CESARI, NICOLA;SPIGHI, ROBERTO;VALENTINETTI, SARA;VILLA, MAURO;Vivarelli, I.;ZOCCOLI, ANTONIO;
2014

Abstract

The semiconductor tracker is a silicon microstrip detector forming part of the inner tracking system of the ATLAS experiment at the LHC. The operation and performance of the semiconductor tracker during the first years of LHC running are described. More than 99% of the detector modules were operational during this period, with an average intrinsic hit efficiency of (99.74±0.04)%. The evolution of the noise occupancy is discussed, and measurements of the Lorentz angle, d-ray production and energy loss presented. The alignment of the detector is found to be stable at the few-micron level over long periods of time. Radiation damage measurements, which include the evolution of detector leakage currents, are found to be consistent with predictions and are used in the verification of radiation background simulations.
2014
The ATLAS collaboration: Aad, G., Abbott, B., Abdallah, J., Abdel Khalek, S., Abdinov, O., Aben, R., et al. (2014). Operation and performance of the ATLAS semiconductor tracker. JOURNAL OF INSTRUMENTATION, 9(8), P08009-1-P08009-74 [10.1088/1748-0221/9/08/P08009].
The ATLAS collaboration: Aad, G.; Abbott, B.; Abdallah, J.; Abdel Khalek, S.; Abdinov, O.; Aben, R.; Abi, B.; Abolins, M.; Abouzeid, O.S.; Abramowicz,...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/544593
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 49
social impact