Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
CRIS Current Research Information System
The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described.
J.A. AGUILAR, A. ALBERT, F. AMELI, M. ANGHINOLFI, G. ANTON, S. ANVAR, et al. (2007). The data acquisition system for the ANTARES neutrino telescope. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 570, 107-116 [10.1016/j.nima.2006.09.098].
The data acquisition system for the ANTARES neutrino telescope
J. A. AGUILAR;A. ALBERT;F. AMELI;M. ANGHINOLFI;G. ANTON;S. ANVAR;E. ASLANIDES;J. J. AUBERT;E. BARBARITO;S. BASA;M. BATTAGLIERI;BECHERINI, YVONNE;R. BELLOTTI;J. BELTRAMELLI;V. BERTIN;A. BIGI;M. BILLAULT;R. BLAES;N. DE BOTTON;M. C. BOUWHUIS;S. M. BRADBURY;R. BRUIJN;J. BRUNNER;G. F. BURGIO;J. BUSTO;F. CAFAGNA;L. CAILLAT;A. CALZAS;A. CAPONE;L. CAPONETTO;E. CARMONA;J. CARR;S. L. CARTWRIGHT;D. CASTEL;E. CASTORINA;V. CAVASINNI;CECCHINI, STEFANO;A. CERES;P. CHARVIS;P. CHAUCHOT;T. CHIARUSI;M. CIRCELLA;C. COLNARD;C. COMPÈRE;R. CONIGLIONE;N. COTTINI;P. COYLE;S. CUNEO;A. S. CUSSATLEGRAS;G. DAMY;R. VAN DANTZIG;C. DE MARZO;I. DEKEYSER;E. DELAGNES;D. DENANS;A. DESCHAMPS;F. DESSAGES ARDELLIER;J. J. DESTELLE;B. DINKESPIELER;C. DISTEFANO;C. DONZAUD;J. F. DROGOU;F. DRUILLOLE;D. DURAND;J. P. ERNENWEIN;S. ESCOFFIER;E. FALCHINI;S. FAVARD;F. FEINSTEIN;S. FERRY;D. FESTY;C. FIORELLO;V. FLAMINIO;S. GALEOTTI;J. M. GALLONE;GIACOMELLI, GIORGIO MARIA;N. GIRARD;C. GOJAK;P.H. GORET;K. GRAF;G. HALLEWELL;M. N. HARAKEH;B. HARTMANN;A. HEIJBOER;E. HEINE;Y. HELLO;J. J. HERNÁNDEZ REY;J. HÖßL;C. HOFFMAN;J. HOGENBIRK;J. R. HUBBARD;M. JAQUET;M. JASPERS;M. DE JONG;F. JOUVENOT;N. KALANTAR NAYESTANAKI;A. KAPPES;T. KARG;S. KARKAR;U. KATZ;P. KELLER;H. KOK;P. KOOIJMAN;C. KOPPER;E. V. KOROLKOVA;A. KOUCHNER;W. KRETSCHMER;A. KRUIJER;S. KUCH;V. A. KUDRYAVSTEV;D. LACHARTRE;H. LAFOUX;P. LAGIER;R. LAHMANN;G. LAMANNA;P. LAMARE;J. C. LANGUILLAT;H. LASCHINSKY;Y. LE GUEN;H. LE PROVOST;A. LE VAN SUU;T. LEGOU;G. LIM;L. LO NIGRO;D. LO PRESTI;H. LOEHNER;S. LOUCATOS;F. LOUIS;F. LUCARELLI;V. LYASHUK;M. MARCELIN;MARGIOTTA, ANNARITA;R. MASULLO;F. MAZÉAS;A. MAZURE;J. E. MCMILLAN;R. MEGNA;M. MELISSAS;E. MIGNECO;A. MILOVANOVIC;M. MONGELLI;T. MONTARULI;M. MORGANTI;L. MOSCOSO;M. MUSUMECI;C. NAUMANN;M. NAUMANN GODO;V. NIESS;C. OLIVETTO;R. OSTASCH;N. PALANQUE DELABROUILLE;P. PAYRE;H. PEEK;C. PETTA;P. PIATTELLI;J. P. PINEAU;J. POINSIGNON;V. POPA;T. PRADIER;C. RACCA;N. RANDAZZO;J. VAN RANDWIJK;D. REAL;B. VAN RENS;F. RÉTHORÉ;P. REWIERSMA;G. RICCOBENE;V. RIGAUD;M. RIPANI;V. ROCA;C. RODA;J. F. ROLIN;M. ROMITA;H. J. ROSE;A. ROSTOVTSEV;J. ROUX;M. RUPPI;G. V. RUSSO;F. SALESA;K. SALOMON;P. SAPIENZA;F. SCHMITT;J. P. SCHULLER;R. SHANIDZE;I. SOKALSKI;T. SPONA;SPURIO, MAURIZIO;G. VAN DER STEENHOVEN;T. STOLARCZYK;K. STREEB;D. STUBERT;L. SULAK;M. TAIUTI;C. TAMBURINI;C. TAO;G. TERRENI;L. F. THOMPSON;P. VALDY;V. VALENTE;B. VALLAGE;G. VENEKAMP;B. VERLAAT;P. VERNIN;R. DE VITA;G. DE VRIES;R. VAN WIJK;P. DE WITT HUBERTS;G. WOBBE;E. DE WOLF;A. F. YAO;D. ZABOROV;H. ZACCONE;J. D. ZORNOZA;J. ZÚÑIGA
2007
Abstract
The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described.
J.A. AGUILAR, A. ALBERT, F. AMELI, M. ANGHINOLFI, G. ANTON, S. ANVAR, et al. (2007). The data acquisition system for the ANTARES neutrino telescope. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 570, 107-116 [10.1016/j.nima.2006.09.098].
J.A. AGUILAR; A. ALBERT; F. AMELI; M. ANGHINOLFI; G. ANTON; S. ANVAR; E. ASLANIDES; J.-J. AUBERT; E. BARBARITO; S. BASA; M. BATTAGLIERI; Y. BECHERINI;...espandi
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/48639
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
176
139
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.