Many measures aiming to assess the stability of human motion have been proposed in the literature, but still there is no commonly accepted way to define or quantify locomotor stability. Among these measures, orbital stability analysis via Floquet multipliers is still under debate. Some of the controversies concerning the use of this technique could lie in the absence of a standard implementation. The aim of this study was to analyse the influence of i) experimental measurement noise, ii) variables selected for the construction of the state space, and iii) number of analysed cycles on the outputs of orbital stability applied to walking. The analysis was performed on a 2-dimensional 5-link walking model and on a sample of 10 subjects performing long over-ground walks. Noise resulting from stereophotogrammetric and accelerometric measurement systems was simulated in the in-silico analysis. Maximum Floquet multipliers resulted to be affected by both number of analysed strides and state space composition. The effect of experimental noise was found to be slightly more potentially critical when analysing stereophotogrammetric data then when dealing with acceleration data. Experimental and model results were comparable in terms of overall trend, but a difference was found in the influence of the number of analysed cycles. © 2013 Riva et al.

Riva F. , Bisi M.C., Stagni R. (2013). Influence of input parameters on dynamic orbital stability of walking: In-silico and experimental evaluation. PLOS ONE, 8(11), 1-7 [10.1371/journal.pone.0080878].

Influence of input parameters on dynamic orbital stability of walking: In-silico and experimental evaluation

RIVA, FEDERICO;BISI, MARIA CRISTINA;STAGNI, RITA
2013

Abstract

Many measures aiming to assess the stability of human motion have been proposed in the literature, but still there is no commonly accepted way to define or quantify locomotor stability. Among these measures, orbital stability analysis via Floquet multipliers is still under debate. Some of the controversies concerning the use of this technique could lie in the absence of a standard implementation. The aim of this study was to analyse the influence of i) experimental measurement noise, ii) variables selected for the construction of the state space, and iii) number of analysed cycles on the outputs of orbital stability applied to walking. The analysis was performed on a 2-dimensional 5-link walking model and on a sample of 10 subjects performing long over-ground walks. Noise resulting from stereophotogrammetric and accelerometric measurement systems was simulated in the in-silico analysis. Maximum Floquet multipliers resulted to be affected by both number of analysed strides and state space composition. The effect of experimental noise was found to be slightly more potentially critical when analysing stereophotogrammetric data then when dealing with acceleration data. Experimental and model results were comparable in terms of overall trend, but a difference was found in the influence of the number of analysed cycles. © 2013 Riva et al.
2013
Riva F. , Bisi M.C., Stagni R. (2013). Influence of input parameters on dynamic orbital stability of walking: In-silico and experimental evaluation. PLOS ONE, 8(11), 1-7 [10.1371/journal.pone.0080878].
Riva F. ; Bisi M.C.; Stagni R.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/354929
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact