PURPOSE: Metabolite ratios are the measurements most commonly utilised for clinical applications of brain proton magnetic resonance spectroscopy ((1)H-MRS) [1]. We evaluated the agreement between the metabolite ratios calculated with semiautomatic and automatic software. MATERIALS AND METHODS: Two single-voxel spectra (3.375 ml) localised in the frontal grey matter (GM) and peritrigonal white matter (WM) were obtained in 20 healthy subjects by using a point-resolved proton spectroscopy sequence (PRESS, TE=144 ms). The spectra were processed using the semiautomatic software J-Magnetic Resonance User Interface (JMRUI) and the automatic software SpectroView. Agreement of the N-acetyl-aspartate (NAA)/creatine (Cr), NAA/choline (Cho) and Cho/Cr ratios calculated with the two methods was assessed by estimating the 95% limits of agreement (LAs) of the differences of the values obtained with the two software packages. RESULTS: Mean values and standard deviations of NAA/Cr, Cho/Cr and NAA/Cho (semiautomatic//automatic software) were 1.99+/-0.53//1.73+/-0.36, 1.13+/-0.40//1.04+/-0.33, 1.85+/-0.62//1.89+/-0.69 for the GM and 2.24+/-0.41//2.37+/-0.27, 0.96+/-0.17//1.13+/-0.15, 2.37+/-0.43//2.11+/-0.23 for the WM. The 95% LAs were wider for GM spectra and ranged between -0.51, 0.17 for Cho/Cr in the WM and -1.54, 1.47 for NAA/Cho in the GM. CONCLUSIONS: The difference between brain metabolite ratios calculated with the two software packages is not negligible and reflects spectral quality.
Mazzoni LN, Belli G, Ginestroni A, Pratesi A, Agnoloni S, Diciotti S, et al. (2010). Computation of brain metabolite ratios in single-voxel proton MR spectroscopy: comparison between semiautomatic and automatic software. LA RADIOLOGIA MEDICA, 115, 125-132 [10.1007/s11547-009-0408-4].
Computation of brain metabolite ratios in single-voxel proton MR spectroscopy: comparison between semiautomatic and automatic software
DICIOTTI, STEFANO;
2010
Abstract
PURPOSE: Metabolite ratios are the measurements most commonly utilised for clinical applications of brain proton magnetic resonance spectroscopy ((1)H-MRS) [1]. We evaluated the agreement between the metabolite ratios calculated with semiautomatic and automatic software. MATERIALS AND METHODS: Two single-voxel spectra (3.375 ml) localised in the frontal grey matter (GM) and peritrigonal white matter (WM) were obtained in 20 healthy subjects by using a point-resolved proton spectroscopy sequence (PRESS, TE=144 ms). The spectra were processed using the semiautomatic software J-Magnetic Resonance User Interface (JMRUI) and the automatic software SpectroView. Agreement of the N-acetyl-aspartate (NAA)/creatine (Cr), NAA/choline (Cho) and Cho/Cr ratios calculated with the two methods was assessed by estimating the 95% limits of agreement (LAs) of the differences of the values obtained with the two software packages. RESULTS: Mean values and standard deviations of NAA/Cr, Cho/Cr and NAA/Cho (semiautomatic//automatic software) were 1.99+/-0.53//1.73+/-0.36, 1.13+/-0.40//1.04+/-0.33, 1.85+/-0.62//1.89+/-0.69 for the GM and 2.24+/-0.41//2.37+/-0.27, 0.96+/-0.17//1.13+/-0.15, 2.37+/-0.43//2.11+/-0.23 for the WM. The 95% LAs were wider for GM spectra and ranged between -0.51, 0.17 for Cho/Cr in the WM and -1.54, 1.47 for NAA/Cho in the GM. CONCLUSIONS: The difference between brain metabolite ratios calculated with the two software packages is not negligible and reflects spectral quality.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.