Few data are available on the effective dose received by participants in lung cancer screening programmes with low-dose CT (LDCT). We report the collective effective dose delivered to 1406 current or former smokers enrolled in the ITALUNG trial who completed 4 annual LDCT examinations and related further investigations including follow-up LDCT, 2-[(18)F]flu-2-deoxy-d-glucose positron emission tomography (FDG-PET) or CT-guided fine needle aspiration biopsy (FNAB). Using the air CT dose index and Monte Carlo simulations on an anthropomorphic phantom, the whole-body effective dose associated with LDCT was determined for the eight CT scanners used in the trial. A value of 7 mSv was assigned to FDG-PET while the measured mean effective dose of CT-guided FNAB was 1.5 mSv. The mean collective effective dose in the 1406 subjects ranged between 8.75 and 9.36 Sv and the mean effective dose to the single subject over 4 years was between 6.2 and 6.8 mSv (range 1.7-21.5 mSv) according to the cranial-caudal length of the LDCT volume. 77.4% of the dose was owing to annual LDCT and 22.6% to further investigations. Considering the nominal risk coefficients for stochastic effects after exposure to low-dose radiation according to the National Radiological Protection Board, International Commission on Radiological Protection (ICRP) 60, ICRP103 and Biological Effects of Ionizing Radiation VII, the mean number of radiation-induced cancers ranged between 0.12 and 0.33 per 1000 subjects. The individual effective dose to participants in a 4-year lung cancer screening programme with annual LDCT is very low and about one-third of the effective dose that is associated with natural background radiation and diagnostic radiology in the same time period.

Dose exposure in the ITALUNG trial lung cancer screening with low-dose CT

DICIOTTI, STEFANO;
2012

Abstract

Few data are available on the effective dose received by participants in lung cancer screening programmes with low-dose CT (LDCT). We report the collective effective dose delivered to 1406 current or former smokers enrolled in the ITALUNG trial who completed 4 annual LDCT examinations and related further investigations including follow-up LDCT, 2-[(18)F]flu-2-deoxy-d-glucose positron emission tomography (FDG-PET) or CT-guided fine needle aspiration biopsy (FNAB). Using the air CT dose index and Monte Carlo simulations on an anthropomorphic phantom, the whole-body effective dose associated with LDCT was determined for the eight CT scanners used in the trial. A value of 7 mSv was assigned to FDG-PET while the measured mean effective dose of CT-guided FNAB was 1.5 mSv. The mean collective effective dose in the 1406 subjects ranged between 8.75 and 9.36 Sv and the mean effective dose to the single subject over 4 years was between 6.2 and 6.8 mSv (range 1.7-21.5 mSv) according to the cranial-caudal length of the LDCT volume. 77.4% of the dose was owing to annual LDCT and 22.6% to further investigations. Considering the nominal risk coefficients for stochastic effects after exposure to low-dose radiation according to the National Radiological Protection Board, International Commission on Radiological Protection (ICRP) 60, ICRP103 and Biological Effects of Ionizing Radiation VII, the mean number of radiation-induced cancers ranged between 0.12 and 0.33 per 1000 subjects. The individual effective dose to participants in a 4-year lung cancer screening programme with annual LDCT is very low and about one-third of the effective dose that is associated with natural background radiation and diagnostic radiology in the same time period.
2012
Mascalchi M; Mazzoni LN; Falchini M; Belli G; Picozzi G; Merlini V; Vella A; Diciotti S; Falaschi F; Lopes Pegna A; Paci E.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/353772
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 42
social impact