Chemically modified electrodes are widely employed in electroanalytical chemistry and an important goal is to strongly anchor redox mediators on the electrode surface. In this work, indium tin oxide (ITO) electrodes have been coated with PEDOT:PSS that has been ferrocene-functionalized, by a two-step procedure consisting of the electrodeposition of PEDOT-N3 followed by copper-catalyzed azide-alkyne cycloaddition of ethynylferrocene. The coated electrodes have been characterized by XPS, showing successful ferrocene immobilization, by AFM, and by cyclic voltammetry (CV), which is dominated by the stable and highly reversible response of ferrocene. The electrocatalytical performance of the device is assessed by analyzing 3,4-dihydroxyphenyl ethylamine, also commonly known as dopamine (DA). The sensor presents a linear range between 0.01 and 0.9 mM, a mean sensitivity of 196 mA M-1 cm-2 and a limit of detection (LoD) of 1 M.

E. Scavetta, R. Mazzoni, F. Mariani, R. G. Margutta, A. Bonfiglio, M. Demelas, et al. (2014). Dopamine amperometric detection at a ferrocene clicked PEDOT:PSS coated electrode. JOURNAL OF MATERIALS CHEMISTRY. B, 2, 2861-2867 [10.1039/c4tb00169a].

Dopamine amperometric detection at a ferrocene clicked PEDOT:PSS coated electrode

SCAVETTA, ERIKA;MAZZONI, RITA;MARIANI, FEDERICA;MARZOCCHI, MARCO;FRABONI, BEATRICE
2014

Abstract

Chemically modified electrodes are widely employed in electroanalytical chemistry and an important goal is to strongly anchor redox mediators on the electrode surface. In this work, indium tin oxide (ITO) electrodes have been coated with PEDOT:PSS that has been ferrocene-functionalized, by a two-step procedure consisting of the electrodeposition of PEDOT-N3 followed by copper-catalyzed azide-alkyne cycloaddition of ethynylferrocene. The coated electrodes have been characterized by XPS, showing successful ferrocene immobilization, by AFM, and by cyclic voltammetry (CV), which is dominated by the stable and highly reversible response of ferrocene. The electrocatalytical performance of the device is assessed by analyzing 3,4-dihydroxyphenyl ethylamine, also commonly known as dopamine (DA). The sensor presents a linear range between 0.01 and 0.9 mM, a mean sensitivity of 196 mA M-1 cm-2 and a limit of detection (LoD) of 1 M.
2014
E. Scavetta, R. Mazzoni, F. Mariani, R. G. Margutta, A. Bonfiglio, M. Demelas, et al. (2014). Dopamine amperometric detection at a ferrocene clicked PEDOT:PSS coated electrode. JOURNAL OF MATERIALS CHEMISTRY. B, 2, 2861-2867 [10.1039/c4tb00169a].
E. Scavetta;R. Mazzoni;F. Mariani;R. G. Margutta;A. Bonfiglio;M. Demelas;S. Fiorilli;M. Marzocchi;B. Fraboni
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/306525
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 39
  • ???jsp.display-item.citation.isi??? 40
social impact