BACKGROUND: The persistence of proviral human immunodeficiency virus type 1 (HIV-1) DNA reservoir represents one of the major drawbacks to the total eradication of HIV-1. The quantitative determination of proviral HIV-1 DNA load offers significant therapeutic information, especially when the HIV-1 RNA levels drop below the detectable limits during the highly active retroviral therapy (HAART) treatment. Moreover, the detection of HIV-1 proviral DNA is an important diagnostic marker in the evaluation of HIV-1 infection of newborns of HIV-1 seropositive women. OBJECTIVE: We evaluated a real-time PCR based on LightCycler technology revealed through SYBR green fluorochrome (SYBR green real-time PCR) to quantify the HIV-1 proviral DNA load in peripheral blood mononuclear cells (PBMC) of HIV-1 seropositive patients. STUDY DESIGN: Firstly, we assessed the SYBR green real-time quantitative PCR for HIV-1 proviral DNA load detection determining the specificity and sensitivity of the assay using the LightCycler system. Secondly, we tested the performance of our SYBR green real-time PCR on 50 HIV-1 seropositive patients under HAART and 20 blood donors. RESULTS/CONCLUSIONS: The results of this study showed that our SYBR green real-time PCR is able to detect five copies of the HIV-1 genome. Moreover, our method revealed HIV-1 proviral DNA in all the 50 HIV-1 seropositive patients ( 627 +/- 1068 HIV-1 proviral DNA copies per 10(6) PBMC, with a range of 30-6300 copies), whereas no positive signal was observed in any PBMC blood donors. Our SYBR green real-time PCR represents a sensitive and useful approach that could be applied both in HIV-1 proviral DNA reservoir determination and in HAART monitoring, particularly when the HIV-1 plasmatic RNA is undetectable.

GIBELLINI D, VITONE F, SCHIAVONE P, PONTI C, LA PLACA M, RE M. (2004). Quantitative detection of human immunodeficiency virus type 1 (HIV-1) proviral DNA in peripheral blood mononuclear cells by SYBR green real-time PCR technique. JOURNAL OF CLINICAL VIROLOGY, 29, 282-289 [10.1016/S1386-6532(03)00169-0].

Quantitative detection of human immunodeficiency virus type 1 (HIV-1) proviral DNA in peripheral blood mononuclear cells by SYBR green real-time PCR technique.

GIBELLINI, DAVIDE;VITONE, FRANCESCA;SCHIAVONE, PASQUA;RE, MARIA CARLA
2004

Abstract

BACKGROUND: The persistence of proviral human immunodeficiency virus type 1 (HIV-1) DNA reservoir represents one of the major drawbacks to the total eradication of HIV-1. The quantitative determination of proviral HIV-1 DNA load offers significant therapeutic information, especially when the HIV-1 RNA levels drop below the detectable limits during the highly active retroviral therapy (HAART) treatment. Moreover, the detection of HIV-1 proviral DNA is an important diagnostic marker in the evaluation of HIV-1 infection of newborns of HIV-1 seropositive women. OBJECTIVE: We evaluated a real-time PCR based on LightCycler technology revealed through SYBR green fluorochrome (SYBR green real-time PCR) to quantify the HIV-1 proviral DNA load in peripheral blood mononuclear cells (PBMC) of HIV-1 seropositive patients. STUDY DESIGN: Firstly, we assessed the SYBR green real-time quantitative PCR for HIV-1 proviral DNA load detection determining the specificity and sensitivity of the assay using the LightCycler system. Secondly, we tested the performance of our SYBR green real-time PCR on 50 HIV-1 seropositive patients under HAART and 20 blood donors. RESULTS/CONCLUSIONS: The results of this study showed that our SYBR green real-time PCR is able to detect five copies of the HIV-1 genome. Moreover, our method revealed HIV-1 proviral DNA in all the 50 HIV-1 seropositive patients ( 627 +/- 1068 HIV-1 proviral DNA copies per 10(6) PBMC, with a range of 30-6300 copies), whereas no positive signal was observed in any PBMC blood donors. Our SYBR green real-time PCR represents a sensitive and useful approach that could be applied both in HIV-1 proviral DNA reservoir determination and in HAART monitoring, particularly when the HIV-1 plasmatic RNA is undetectable.
2004
GIBELLINI D, VITONE F, SCHIAVONE P, PONTI C, LA PLACA M, RE M. (2004). Quantitative detection of human immunodeficiency virus type 1 (HIV-1) proviral DNA in peripheral blood mononuclear cells by SYBR green real-time PCR technique. JOURNAL OF CLINICAL VIROLOGY, 29, 282-289 [10.1016/S1386-6532(03)00169-0].
GIBELLINI D; VITONE F; SCHIAVONE P; PONTI C; LA PLACA M; RE M.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/2364
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 88
  • ???jsp.display-item.citation.isi??? 83
social impact