We process the total-station surveys performed at the ITRF co-location site Medicina (Northern Italy) over the decade (2001–2010) with the purpose of determining the extent of local intrasite motions and relating them to local geophysical processes, the geological setting and the design of the ground pillars. In addition, continuous observations acquired by two co-located GPS stations (MEDI and MSEL separated by ≈27 m) are analysed and their relative motion is cross-checked with the total-station results. The local ground control network extends over a small area (<100 × 100 m) but the results demonstrate significant anisotropic deformations with rates up to 1.6 mm a−1, primarily horizontal, a value comparable to intraplate tectonic deformations. The results derived from GPS and total-station observations are consistent and point to the presence of horizontal intrasite motions over very short distances possibly associated with varying environmental conditions in a very unfavourable local geological setting and unsuitable monument design, these latter being crucial aspects of the realization and maintenance of global permanent geodetic networks and the global terrestrial reference frame.

Intrasite motions and monument instabilities at Medicina ITRF co-location site / Sarti P.; Abbondanza C.; Legrand J.; Bruyninx C.; Vittuari L.; Ray J.. - In: GEOPHYSICAL JOURNAL INTERNATIONAL. - ISSN 0956-540X. - STAMPA. - 192:(2013), pp. 1042-1051. [10.1093/gji/ggs092]

Intrasite motions and monument instabilities at Medicina ITRF co-location site

VITTUARI, LUCA;
2013

Abstract

We process the total-station surveys performed at the ITRF co-location site Medicina (Northern Italy) over the decade (2001–2010) with the purpose of determining the extent of local intrasite motions and relating them to local geophysical processes, the geological setting and the design of the ground pillars. In addition, continuous observations acquired by two co-located GPS stations (MEDI and MSEL separated by ≈27 m) are analysed and their relative motion is cross-checked with the total-station results. The local ground control network extends over a small area (<100 × 100 m) but the results demonstrate significant anisotropic deformations with rates up to 1.6 mm a−1, primarily horizontal, a value comparable to intraplate tectonic deformations. The results derived from GPS and total-station observations are consistent and point to the presence of horizontal intrasite motions over very short distances possibly associated with varying environmental conditions in a very unfavourable local geological setting and unsuitable monument design, these latter being crucial aspects of the realization and maintenance of global permanent geodetic networks and the global terrestrial reference frame.
2013
Intrasite motions and monument instabilities at Medicina ITRF co-location site / Sarti P.; Abbondanza C.; Legrand J.; Bruyninx C.; Vittuari L.; Ray J.. - In: GEOPHYSICAL JOURNAL INTERNATIONAL. - ISSN 0956-540X. - STAMPA. - 192:(2013), pp. 1042-1051. [10.1093/gji/ggs092]
Sarti P.; Abbondanza C.; Legrand J.; Bruyninx C.; Vittuari L.; Ray J.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/145080
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact