New measurements of the total and partial fragmentation cross-sections in the energy range 0.3 ÷ 10 A GeV of Fe26+, Si14+ and C6+ beams on polyethylene, CR-39 and aluminum targets are presented. The exposures were made at Brookhaven National Laboratory (BNL), USA, and Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. The CR-39 nuclear track detectors were used to identify the incident and survived beam ions and their fragments. The total fragmentation cross-sections for all targets are almost energy independent while they depend on the target mass. The measured partial fragmentation cross-sections are also discussed.

S. Cecchini, T. Chiarusi, G. Giacomelli, A. Kumar, G. Mandrioli, S. Manzoor, et al. (2009). Fragmentation cross-sections of Fe26+, Si14+ and C6+ ions of 0.3 ÷ 10 A GeV on polyethylene, CR-39 and aluminum targets. RADIATION MEASUREMENTS, 44, 853-856 [10.1016/j.radmeas.2009.10.032].

Fragmentation cross-sections of Fe26+, Si14+ and C6+ ions of 0.3 ÷ 10 A GeV on polyethylene, CR-39 and aluminum targets

CECCHINI, STEFANO;CHIARUSI, TOMMASO;GIACOMELLI, GIORGIO MARIA;MARGIOTTA, ANNARITA;MEDINACELI VILLEGAS, EDUARDO;PATRIZII, LAURA;POPA, VLAD;SIRRI, GABRIELE;SPURIO, MAURIZIO;
2009

Abstract

New measurements of the total and partial fragmentation cross-sections in the energy range 0.3 ÷ 10 A GeV of Fe26+, Si14+ and C6+ beams on polyethylene, CR-39 and aluminum targets are presented. The exposures were made at Brookhaven National Laboratory (BNL), USA, and Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. The CR-39 nuclear track detectors were used to identify the incident and survived beam ions and their fragments. The total fragmentation cross-sections for all targets are almost energy independent while they depend on the target mass. The measured partial fragmentation cross-sections are also discussed.
2009
S. Cecchini, T. Chiarusi, G. Giacomelli, A. Kumar, G. Mandrioli, S. Manzoor, et al. (2009). Fragmentation cross-sections of Fe26+, Si14+ and C6+ ions of 0.3 ÷ 10 A GeV on polyethylene, CR-39 and aluminum targets. RADIATION MEASUREMENTS, 44, 853-856 [10.1016/j.radmeas.2009.10.032].
S. Cecchini; T. Chiarusi; G. Giacomelli; A. Kumar; G. Mandrioli; S. Manzoor; A.R. Margiotta; E. Medinaceli; L. Patrizii; V. Popa; I.E. Qureshi; Z. Sah...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/126166
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact