Background Endoscopic ultrasound (EUS)-guided drainage of pancreatic fluid collections (PFCs) by cautery-enhanced lumen-apposing metal stents (LAMS) has largely been limited to collections located <10mm from the luminal wall. We present outcomes of the use of a novel 15-mm-long cautery-enhanced LAMS for drainage of PFCs located ≥10mm away. Methods This international, multicenter study analyzed all adults with PFCs located ≥10mm from the luminal wall who were treated by EUS-guided drainage using the 15-mm-long cautery-enhanced LAMS. The primary outcome was technical success. Secondary outcomes included clinical success (decrease in PFC size by≥50% at 30 days and resolution of clinical symptoms without surgical intervention), complications, and recurrence. Results 35 patients (median age 57 years; interquartile range [IQR] 47-64 years; 49% male) underwent novel LAMS placement for drainage of PFCs (26 walled-off necrosis, 9 pseudocysts), measuring 85mm (IQR 64-117) maximal diameter and located 11.8mm (IQR 10-12.3; range 10-14) from the gastric/duodenal wall. Technical and clinical success were high (both 97%), with recurrence in one patient (3%) at a median follow-up of 123 days (58-236). Three complications occurred (9%; one mild, two moderate). Conclusions The 15-mm-long cautery-enhanced LAMS was feasible and safe for drainage of PFCs located 10-14mm from the luminal wall.
Zhang, L.Y., Kunda, R., Aerts, M., Messaoudi, N., Pawa, R., Pawa, S., et al. (2022). Novel 15-mm-long lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections located ≥10 mm from the luminal wall. ENDOSCOPY, 54(7), 706-711 [10.1055/a-1682-7095].
Novel 15-mm-long lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections located ≥10 mm from the luminal wall
Fabbri C.;Binda C.;Tarantino I.;Singh V.;
2022
Abstract
Background Endoscopic ultrasound (EUS)-guided drainage of pancreatic fluid collections (PFCs) by cautery-enhanced lumen-apposing metal stents (LAMS) has largely been limited to collections located <10mm from the luminal wall. We present outcomes of the use of a novel 15-mm-long cautery-enhanced LAMS for drainage of PFCs located ≥10mm away. Methods This international, multicenter study analyzed all adults with PFCs located ≥10mm from the luminal wall who were treated by EUS-guided drainage using the 15-mm-long cautery-enhanced LAMS. The primary outcome was technical success. Secondary outcomes included clinical success (decrease in PFC size by≥50% at 30 days and resolution of clinical symptoms without surgical intervention), complications, and recurrence. Results 35 patients (median age 57 years; interquartile range [IQR] 47-64 years; 49% male) underwent novel LAMS placement for drainage of PFCs (26 walled-off necrosis, 9 pseudocysts), measuring 85mm (IQR 64-117) maximal diameter and located 11.8mm (IQR 10-12.3; range 10-14) from the gastric/duodenal wall. Technical and clinical success were high (both 97%), with recurrence in one patient (3%) at a median follow-up of 123 days (58-236). Three complications occurred (9%; one mild, two moderate). Conclusions The 15-mm-long cautery-enhanced LAMS was feasible and safe for drainage of PFCs located 10-14mm from the luminal wall.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.