Muscle activity during exercise is typically assessed using oximeters, to evaluate local oxygen saturation (SmO2), or surface electromyography (sEMG), to analyze electrical activation. Despite the importance of combining these analyses, no study has evaluated both of them during specific swimming exercises in combination with mechanical power output. This study aimed to assess muscle activity during an incremental test on a swim-bench utilizing oximeters and sEMG. Nine male swimmers performed a five-steps test: PRE (3 min at rest), STEP 1, 2, and 3 (swimming at a frequency of 25, 30, and 40 cycle/min for a duration of 2, 2, and 1 min, respectively), and POST (5 min at rest). Each swimmer wore two oximeters and sEMG, one for each triceps brachii. Stroke frequency and arm mechanical power (from ~13 to ~52 watts) estimated by the swim-bench were different among all steps, while no differences between arms were found. SmO2 (from ~70% to ~60%) and sEMG signals (from ~20 to ~65% in signal amplitude) showed a significant increase among all steps. In both arms, a large/very large correlation was found between mechanical power and SmO2 (r < −0.634), mechanical power and sEMG onset/amplitude (r > 0.581), and SmO2 and sEMG amplitude (r > 0.508). No correlations were found between the slope of the sEMG spectral indexes and the slope of SmO2; only sEMG detected electrical manifestation of muscle fatigue through the steps (p < 0.05). Increased muscle activity, assessed by both oximeters and sEMG, was found at mechanical power increases, revealing both devices can detect effort variation during exercise. However, only sEMG seems to detect peripheral manifestations of fatigue in dynamic conditions.
Coloretti, V., Quagliarotti, C., Gatta, G., Piacentini, M.F., Cortesi, M., Fantozzi, S. (2025). Interplay Among Muscle Oxygen Saturation, Activation, and Power on a Swim-Bench. SENSORS, 25(13), 1-16 [10.3390/s25134148].
Interplay Among Muscle Oxygen Saturation, Activation, and Power on a Swim-Bench
Coloretti V.Primo
;Gatta G.;Cortesi M.;Fantozzi S.Ultimo
2025
Abstract
Muscle activity during exercise is typically assessed using oximeters, to evaluate local oxygen saturation (SmO2), or surface electromyography (sEMG), to analyze electrical activation. Despite the importance of combining these analyses, no study has evaluated both of them during specific swimming exercises in combination with mechanical power output. This study aimed to assess muscle activity during an incremental test on a swim-bench utilizing oximeters and sEMG. Nine male swimmers performed a five-steps test: PRE (3 min at rest), STEP 1, 2, and 3 (swimming at a frequency of 25, 30, and 40 cycle/min for a duration of 2, 2, and 1 min, respectively), and POST (5 min at rest). Each swimmer wore two oximeters and sEMG, one for each triceps brachii. Stroke frequency and arm mechanical power (from ~13 to ~52 watts) estimated by the swim-bench were different among all steps, while no differences between arms were found. SmO2 (from ~70% to ~60%) and sEMG signals (from ~20 to ~65% in signal amplitude) showed a significant increase among all steps. In both arms, a large/very large correlation was found between mechanical power and SmO2 (r < −0.634), mechanical power and sEMG onset/amplitude (r > 0.581), and SmO2 and sEMG amplitude (r > 0.508). No correlations were found between the slope of the sEMG spectral indexes and the slope of SmO2; only sEMG detected electrical manifestation of muscle fatigue through the steps (p < 0.05). Increased muscle activity, assessed by both oximeters and sEMG, was found at mechanical power increases, revealing both devices can detect effort variation during exercise. However, only sEMG seems to detect peripheral manifestations of fatigue in dynamic conditions.| File | Dimensione | Formato | |
|---|---|---|---|
|
Coloretti et al. - 2025 - Interplay Among Muscle Oxygen Saturation, Activati.pdf
accesso aperto
Tipo:
Versione (PDF) editoriale / Version Of Record
Licenza:
Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione
2.19 MB
Formato
Adobe PDF
|
2.19 MB | Adobe PDF | Visualizza/Apri |
|
sensors-25-04148-s001.zip
accesso aperto
Tipo:
File Supplementare
Licenza:
Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione
499.06 kB
Formato
Zip File
|
499.06 kB | Zip File | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.