This study presents a novel approach for EEG-based seizure detection leveraging a BERT-based model. The model, BENDR, undergoes a two-phase training process. Initially, it is pre-trained on the extensive Temple University Hospital EEG Corpus (TUEG), a 1.5 TB dataset comprising over 10,000 subjects, to extract common EEG data patterns. Subsequently, the model is fine-tuned on the CHB-MIT Scalp EEG Database, consisting of 664 EEG recordings from 24 pediatric patients, of which 198 contain seizure events. Key contributions include optimizing fine-tuning on the CHB-MIT dataset, where the impact of model architecture, pre-processing, and post-processing techniques are thoroughly examined to enhance sensitivity and reduce false positives per hour (FP/h). We also explored custom training strategies to ascertain the most effective setup. The model undergoes a novel second pre-training phase before subject-specific fine-tuning, enhancing its generalization capabilities. The optimized model demonstrates substantial performance enhancements, achieving as low as 0.23 FP/h, 2.5× lower than the baseline model, with a lower but still acceptable sensitivity rate, showcasing the effectiveness of applying a BERT-based approach on EEG-based seizure detection.Clinical relevance - The model enhances clinical seizure detection, offering personalized treatments and better generalization to new patients, akin to successes with transformer-based models, thus significantly improving patient safety and care.

Benfenati, L., Ingolfsson, T.M., Cossettini, A., Pagliari, D.J., Burrello, A., Benini, L. (2024). BISeizuRe: BERT-Inspired Seizure Data Representation to Improve Epilepsy Monitoring. Institute of Electrical and Electronics Engineers Inc. [10.1109/EMBC53108.2024.10782289].

BISeizuRe: BERT-Inspired Seizure Data Representation to Improve Epilepsy Monitoring

Benfenati L.;Benini L.
2024

Abstract

This study presents a novel approach for EEG-based seizure detection leveraging a BERT-based model. The model, BENDR, undergoes a two-phase training process. Initially, it is pre-trained on the extensive Temple University Hospital EEG Corpus (TUEG), a 1.5 TB dataset comprising over 10,000 subjects, to extract common EEG data patterns. Subsequently, the model is fine-tuned on the CHB-MIT Scalp EEG Database, consisting of 664 EEG recordings from 24 pediatric patients, of which 198 contain seizure events. Key contributions include optimizing fine-tuning on the CHB-MIT dataset, where the impact of model architecture, pre-processing, and post-processing techniques are thoroughly examined to enhance sensitivity and reduce false positives per hour (FP/h). We also explored custom training strategies to ascertain the most effective setup. The model undergoes a novel second pre-training phase before subject-specific fine-tuning, enhancing its generalization capabilities. The optimized model demonstrates substantial performance enhancements, achieving as low as 0.23 FP/h, 2.5× lower than the baseline model, with a lower but still acceptable sensitivity rate, showcasing the effectiveness of applying a BERT-based approach on EEG-based seizure detection.Clinical relevance - The model enhances clinical seizure detection, offering personalized treatments and better generalization to new patients, akin to successes with transformer-based models, thus significantly improving patient safety and care.
2024
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
1
4
Benfenati, L., Ingolfsson, T.M., Cossettini, A., Pagliari, D.J., Burrello, A., Benini, L. (2024). BISeizuRe: BERT-Inspired Seizure Data Representation to Improve Epilepsy Monitoring. Institute of Electrical and Electronics Engineers Inc. [10.1109/EMBC53108.2024.10782289].
Benfenati, L.; Ingolfsson, T. M.; Cossettini, A.; Pagliari, D. J.; Burrello, A.; Benini, L.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1004836
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact