Capacitive noncontact electrodes offer a promising solution to improve comfort and unobtrusiveness in continuous monitoring ECG systems which are becoming more widespread in wearable devices. Most implementations based on off-the-shelf components require rather large electrodes and power budgets while custom application-specific integrated circuits (ASICs) face significantly higher adoption challenges. In this article, we present a novel micropower ultrahigh impedance front-end with an equivalent input capacitance of 70 fF in the ECG band, enabling contactless ECG acquisition with electrodes as small as 78.5 mm2 with a power consumption of only $15 \, \mu \text{W}$. The front-end implements a novel power supply bootstrapping architecture and is integrated in a full acquisition system which includes a 24-bit analog to digital converter (ADC) and a bluetooth low energy (BLE)-capable Cortex M4 processor, achieving up to ten days of continuous operation on a 600 mAh PR44 battery.

Guermandi, M., Benatti, S., Benini, L. (2024). A Noncontact ECG Sensing System With a Micropower, Ultrahigh Impedance Front-End, and BLE Connectivity. IEEE SENSORS JOURNAL, 24(4), 4609-4617 [10.1109/JSEN.2023.3347100].

A Noncontact ECG Sensing System With a Micropower, Ultrahigh Impedance Front-End, and BLE Connectivity

Guermandi M.;Benatti S.;Benini L.
2024

Abstract

Capacitive noncontact electrodes offer a promising solution to improve comfort and unobtrusiveness in continuous monitoring ECG systems which are becoming more widespread in wearable devices. Most implementations based on off-the-shelf components require rather large electrodes and power budgets while custom application-specific integrated circuits (ASICs) face significantly higher adoption challenges. In this article, we present a novel micropower ultrahigh impedance front-end with an equivalent input capacitance of 70 fF in the ECG band, enabling contactless ECG acquisition with electrodes as small as 78.5 mm2 with a power consumption of only $15 \, \mu \text{W}$. The front-end implements a novel power supply bootstrapping architecture and is integrated in a full acquisition system which includes a 24-bit analog to digital converter (ADC) and a bluetooth low energy (BLE)-capable Cortex M4 processor, achieving up to ten days of continuous operation on a 600 mAh PR44 battery.
2024
Guermandi, M., Benatti, S., Benini, L. (2024). A Noncontact ECG Sensing System With a Micropower, Ultrahigh Impedance Front-End, and BLE Connectivity. IEEE SENSORS JOURNAL, 24(4), 4609-4617 [10.1109/JSEN.2023.3347100].
Guermandi, M.; Benatti, S.; Benini, L.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1004677
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact