We describe a case of an abdominal aortic aneurysm (AAA) and angulated proximal neck treated with a Gore Excluder conformable endoprosthesis and show relevant technical pitfalls in the deployment of the graft main body. An 82-year-old man presented with a 71-mm asymptomatic AAA with an angulated infrarenal proximal neck (75 degrees) and was referred to our unit. The patient was treated with a 26-mm Gore Excluder conformable device, which was deployed slightly above the renal arteries after precatheterization of the lowest renal artery. The graft was then repositioned with support of the introducer sheath and a stiff guide wire. The proximal sealing zone was ballooned before the endograft delivery system was retrieved to avoid distal migration. Technical success was achieved. The patient was discharged with no complications. No type Ia endoleak was present on the 6-month computed tomography scan. Endovascular treatment of an AAA with a severe angulated proximal neck can be effective with a conformable stent graft if technical measures are used during deployment of the main body to optimize the seal.
Vacirca, A., Sulzer, T.A.L., Mesnard, T., Baghbani-Oskouei, A., Ocasio, L., Macedo, T.A., et al. (2023). Technical pitfalls and proposed modifications of instructions for use for endovascular aortic aneurysm repair using the Gore Excluder conformable device in angulated and short landing zones. JOURNAL OF VASCULAR SURGERY CASES AND INNOVATIVE TECHNIQUES, 9(4), 1-4 [10.1016/j.jvscit.2023.101339].
Technical pitfalls and proposed modifications of instructions for use for endovascular aortic aneurysm repair using the Gore Excluder conformable device in angulated and short landing zones
Vacirca A.;
2023
Abstract
We describe a case of an abdominal aortic aneurysm (AAA) and angulated proximal neck treated with a Gore Excluder conformable endoprosthesis and show relevant technical pitfalls in the deployment of the graft main body. An 82-year-old man presented with a 71-mm asymptomatic AAA with an angulated infrarenal proximal neck (75 degrees) and was referred to our unit. The patient was treated with a 26-mm Gore Excluder conformable device, which was deployed slightly above the renal arteries after precatheterization of the lowest renal artery. The graft was then repositioned with support of the introducer sheath and a stiff guide wire. The proximal sealing zone was ballooned before the endograft delivery system was retrieved to avoid distal migration. Technical success was achieved. The patient was discharged with no complications. No type Ia endoleak was present on the 6-month computed tomography scan. Endovascular treatment of an AAA with a severe angulated proximal neck can be effective with a conformable stent graft if technical measures are used during deployment of the main body to optimize the seal.| File | Dimensione | Formato | |
|---|---|---|---|
|
Conformable Technical Pitfalls.pdf
accesso aperto
Tipo:
Versione (PDF) editoriale / Version Of Record
Licenza:
Licenza per Accesso Aperto. Creative Commons Attribuzione - Non commerciale - Non opere derivate (CCBYNCND)
Dimensione
607.59 kB
Formato
Adobe PDF
|
607.59 kB | Adobe PDF | Visualizza/Apri |
|
ScienceDirect_files_12Sep2025_12-31-19.934.zip
accesso aperto
Tipo:
File Supplementare
Licenza:
Licenza per Accesso Aperto. Creative Commons Attribuzione - Non commerciale - Non opere derivate (CCBYNCND)
Dimensione
52.28 MB
Formato
Zip File
|
52.28 MB | Zip File | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.