When exposed to an intense radiation field, the spectroscopic capabilities of room-temperature CdTe and CdZnTe detectors can be strongly altered by the remarkable injection of energy in the material structure due to the absorption of ionizing particles. In this paper, we report on the effects of electron irradiation on both CdTe and CdZnTe detectors. We have studied the detector response to electron irradiation through dark current measurements and by spectroscopic analyses at low and medium energies. The deep traps present in the material have been characterized by means of photo-induced current transient spectroscopy analyses, which allow for the determination of the trap apparent activation energy and capture cross section. The evolution of the trap parameters with increasing irradiation doses has been monitored and compared with the results already obtained by using other radiation sources.

Cavallini, A., Fraboni, B., Dusi, W., Auricchio, N., Chirco, P., Zanarini, M., et al. (2002). Behavior of CdTe and CdZnTe detectors following electron irradiation. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 49(4), 1598-1602 [10.1109/TNS.2002.801683].

Behavior of CdTe and CdZnTe detectors following electron irradiation

Cavallini A.;Fraboni B.;Auricchio N.;Chirco P.;Zanarini M.;
2002

Abstract

When exposed to an intense radiation field, the spectroscopic capabilities of room-temperature CdTe and CdZnTe detectors can be strongly altered by the remarkable injection of energy in the material structure due to the absorption of ionizing particles. In this paper, we report on the effects of electron irradiation on both CdTe and CdZnTe detectors. We have studied the detector response to electron irradiation through dark current measurements and by spectroscopic analyses at low and medium energies. The deep traps present in the material have been characterized by means of photo-induced current transient spectroscopy analyses, which allow for the determination of the trap apparent activation energy and capture cross section. The evolution of the trap parameters with increasing irradiation doses has been monitored and compared with the results already obtained by using other radiation sources.
2002
Cavallini, A., Fraboni, B., Dusi, W., Auricchio, N., Chirco, P., Zanarini, M., et al. (2002). Behavior of CdTe and CdZnTe detectors following electron irradiation. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 49(4), 1598-1602 [10.1109/TNS.2002.801683].
Cavallini, A.; Fraboni, B.; Dusi, W.; Auricchio, N.; Chirco, P.; Zanarini, M.; Siffert, P.; Fougeres, P.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/1001734
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? ND
social impact