In this paper, the IEC 60034-18-41 technical standard procedures for assessing the quality of Type I (random wound) motors through (offline) partial discharge testing are briefly summarized first. After, offline and online measurements performed on one motor, able to pass the tests but failed soon after energization through a PWM inverter, will be compared. The analysis will highlight the pros and cons of the standard.

Electrical aging of inverter-fed wire-wound induction motors: from quality control to end of life

CAVALLINI, ANDREA;MONTANARI, GIAN CARLO;TOZZI, MARCO
2010

Abstract

In this paper, the IEC 60034-18-41 technical standard procedures for assessing the quality of Type I (random wound) motors through (offline) partial discharge testing are briefly summarized first. After, offline and online measurements performed on one motor, able to pass the tests but failed soon after energization through a PWM inverter, will be compared. The analysis will highlight the pros and cons of the standard.
Conference Record of the 2010 IEEE International Symposium on Electrical Insulation (ISEI)
1
4
A. Cavallini; G. C. Montanari; M. Tozzi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/99060
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 0
social impact