This article is the first of a series of three that examines the correlation between off-line and on-line measurements on Type I random-wound motors. The off-line tests reported in this first article were carried out according to IEC 60034-18-4 to demonstrate that they are PD free under impulsive voltage conditions.

M. Tozzi, A. Cavallini, G. C. Montanari (2010). Monitoring off-line and on-line PD under impulsive voltage on induction motors - part I: standard procedure. IEEE ELECTRICAL INSULATION MAGAZINE, 26, 16-26 [10.1109/MEI.2010.5511185].

Monitoring off-line and on-line PD under impulsive voltage on induction motors - part I: standard procedure

TOZZI, MARCO;CAVALLINI, ANDREA;MONTANARI, GIAN CARLO
2010

Abstract

This article is the first of a series of three that examines the correlation between off-line and on-line measurements on Type I random-wound motors. The off-line tests reported in this first article were carried out according to IEC 60034-18-4 to demonstrate that they are PD free under impulsive voltage conditions.
2010
M. Tozzi, A. Cavallini, G. C. Montanari (2010). Monitoring off-line and on-line PD under impulsive voltage on induction motors - part I: standard procedure. IEEE ELECTRICAL INSULATION MAGAZINE, 26, 16-26 [10.1109/MEI.2010.5511185].
M. Tozzi; A. Cavallini; G. C. Montanari
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/99054
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 62
  • ???jsp.display-item.citation.isi??? 50
social impact