This study aimed to develop and validate the tendinopathy hemophilia detection with ultrasonography (THD-US) protocol for assessing hemophilia-related tendinopathy. Twenty male patients with hemophilic arthropathy underwent ultrasound evaluations of 200 tendons. The THD-US scoring method assessed structural changes, hyper- emia, and calcifications, revealing various tendon abnormalities. This protocol pro- vides a standardized, efficient method for assessing tendinopathy in hemophilia patients, potentially improving patient management and outcomes.
Danilo Donati, F.O. (2024). Ultrasound assessment and scoring of tendinopathy in hemophilia: Development of the Tendon Haemophilic Damage - Ultrasound (THD-US) method. JOURNAL OF CLINICAL ULTRASOUND, 53, 1-6.
Ultrasound assessment and scoring of tendinopathy in hemophilia: Development of the Tendon Haemophilic Damage - Ultrasound (THD-US) method
Danilo Donati;Flavio Origlio;Stefano Galletti;Marco Miceli;Paolo Spinnato;Lydia Piscitelli;Vincenzo Ricci;Fabio Vita;Roberto Tedeschi;Maria Grazia Benedetti
2024
Abstract
This study aimed to develop and validate the tendinopathy hemophilia detection with ultrasonography (THD-US) protocol for assessing hemophilia-related tendinopathy. Twenty male patients with hemophilic arthropathy underwent ultrasound evaluations of 200 tendons. The THD-US scoring method assessed structural changes, hyper- emia, and calcifications, revealing various tendon abnormalities. This protocol pro- vides a standardized, efficient method for assessing tendinopathy in hemophilia patients, potentially improving patient management and outcomes.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.