Objectives To describe the new semisynthetic total ossicular replacement prosthesis (New-SSTORP) and to evaluate the New-SSTORP ossiculoplasty results both with the presence and absence of the stapes superstructure. Study Design Prospective study. Setting Tertiary referral center. Methods From April 2023 to May 2023, 18 New-SSTORP ossiculoplasties were performed by the first author. In all patients, the New-SSTORP was interposed between the footplate and the eardrum. The study group was divided into two groups (group A and group B). Group A included 13 patients with the absence of stapes superstructure. Group B included five patients with the presence of stapes superstructure. A successful reconstruction was defined as a postoperative air-bone gap ABG ≤20 dB. For all patients of groups A and B, the last audiometric control considered was performed in January 2024. The mean follow-up was 8½ months. The χ2 test was used to compare results. p < 0.05 was considered significant. Main Outcome Measures Mean postoperative ABG ≤20 dB Results At the end of follow-up, the overall success rate (ABG ≤20 dB) of New-SSTORP ossiculoplasty was obtained in 88.8% (n = 16 of 18) of cases. In group A, the success rate of New-SSTORP ossiculoplasty occurred in 84.6% (n = 11 of 13) of cases, and in group B, the success rate of New-SSTORP ossiculoplasty occurred in 100% (n = 5 of 5) of cases. There was no audiological statistically significant difference between groups A and B (Fisher value is 1; p < 0.05). In all cases, the time for positioning of New-SSTORP was about 5 minutes Conclusion The New-SSTORP has a minimal technical challenge for building and placement. The New-SSTORP ossiculoplasty results are very good both with the presence and absence of SS.
Malafronte G., Fetoni A.R., Motta G., Presutti L. (2024). The New Semisynthetic TORP: A Prosthesis for Ossicular Reconstruction Both with the Absence and the Presence of the Stapes Superstructure. OTOLOGY & NEUROTOLOGY, 45(7), 783-789 [10.1097/MAO.0000000000004244].
The New Semisynthetic TORP: A Prosthesis for Ossicular Reconstruction Both with the Absence and the Presence of the Stapes Superstructure
Presutti L.
2024
Abstract
Objectives To describe the new semisynthetic total ossicular replacement prosthesis (New-SSTORP) and to evaluate the New-SSTORP ossiculoplasty results both with the presence and absence of the stapes superstructure. Study Design Prospective study. Setting Tertiary referral center. Methods From April 2023 to May 2023, 18 New-SSTORP ossiculoplasties were performed by the first author. In all patients, the New-SSTORP was interposed between the footplate and the eardrum. The study group was divided into two groups (group A and group B). Group A included 13 patients with the absence of stapes superstructure. Group B included five patients with the presence of stapes superstructure. A successful reconstruction was defined as a postoperative air-bone gap ABG ≤20 dB. For all patients of groups A and B, the last audiometric control considered was performed in January 2024. The mean follow-up was 8½ months. The χ2 test was used to compare results. p < 0.05 was considered significant. Main Outcome Measures Mean postoperative ABG ≤20 dB Results At the end of follow-up, the overall success rate (ABG ≤20 dB) of New-SSTORP ossiculoplasty was obtained in 88.8% (n = 16 of 18) of cases. In group A, the success rate of New-SSTORP ossiculoplasty occurred in 84.6% (n = 11 of 13) of cases, and in group B, the success rate of New-SSTORP ossiculoplasty occurred in 100% (n = 5 of 5) of cases. There was no audiological statistically significant difference between groups A and B (Fisher value is 1; p < 0.05). In all cases, the time for positioning of New-SSTORP was about 5 minutes Conclusion The New-SSTORP has a minimal technical challenge for building and placement. The New-SSTORP ossiculoplasty results are very good both with the presence and absence of SS.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.