IntroductionThe aim of this sub-study was to evaluate the relationship between echocardiography (echo) and cardiac magnetic resonance imaging (cMRI) variables and to utilize echo to assess the effect of macitentan on right ventricle (RV) structure and function.MethodsREPAIR (NCT02310672) was a prospective, multicenter, single-arm, open-label, 52-week, phase 4 study in pulmonary arterial hypertension (PAH) patients, which investigated the effect of macitentan 10 mg as monotherapy, or in combination with a phosphodiesterase 5 inhibitor, on RV structure, function, and hemodynamics using cMRI and right heart catheterization. In this sub-study, patients were also assessed by echo at screening and at weeks 26 and/or 52. Post hoc correlation analyses between echo and cMRI variables were performed using Pearson's correlation coefficient, Spearman's correlation coefficient, and Bland-Altman analyses.ResultsThe Echo sub-study included 45 patients. Improvements in echo-assessed RV stroke volume (RVSV), left ventricular SV (LVSV), LV end-diastolic volume (LVEDV), RV fractional area change (RVFAC), tricuspid annular plane systolic excursion (TAPSE), and in 2D global longitudinal RV strain (2D GLRVS) were observed at weeks 26 and 52 compared to baseline. There was a strong correlation between echo (LVSV, 2D GLRVS, and LVEDV) and cMRI variables, with a moderate correlation for RVSV. Bland-Altman analyses showed a good agreement for LVSV measured by echo versus cMRI, whereas an overestimation in echo-assessed RVSV was observed compared to cMRI (bias of - 15 mL). Hemodynamic and functional variables, as well as safety, were comparable between the Echo sub-study and REPAIR.ConclusionsA good relationship between relevant echo and cMRI parameters was shown. Improvements in RV structure and function with macitentan treatment was observed by echo, consistent with results observed by cMRI in the primary analysis of the REPAIR study. Echo is a valuable complementary method to cMRI, with the potential to non-invasively monitor treatment response at follow-up.Trial registration numberREPAIR NCT02310672.

Torbicki, A., Channick, R., Galiè, N., Kiely, D.G., Moceri, P., Peacock, A., et al. (2024). Effect of Macitentan in Pulmonary Arterial Hypertension and the Relationship Between Echocardiography and cMRI Variables: REPAIR Echocardiography Sub-study Results. CARDIOLOGY AND THERAPY, 13(1), 173-190 [10.1007/s40119-023-00345-2].

Effect of Macitentan in Pulmonary Arterial Hypertension and the Relationship Between Echocardiography and cMRI Variables: REPAIR Echocardiography Sub-study Results

Galiè N.;
2024

Abstract

IntroductionThe aim of this sub-study was to evaluate the relationship between echocardiography (echo) and cardiac magnetic resonance imaging (cMRI) variables and to utilize echo to assess the effect of macitentan on right ventricle (RV) structure and function.MethodsREPAIR (NCT02310672) was a prospective, multicenter, single-arm, open-label, 52-week, phase 4 study in pulmonary arterial hypertension (PAH) patients, which investigated the effect of macitentan 10 mg as monotherapy, or in combination with a phosphodiesterase 5 inhibitor, on RV structure, function, and hemodynamics using cMRI and right heart catheterization. In this sub-study, patients were also assessed by echo at screening and at weeks 26 and/or 52. Post hoc correlation analyses between echo and cMRI variables were performed using Pearson's correlation coefficient, Spearman's correlation coefficient, and Bland-Altman analyses.ResultsThe Echo sub-study included 45 patients. Improvements in echo-assessed RV stroke volume (RVSV), left ventricular SV (LVSV), LV end-diastolic volume (LVEDV), RV fractional area change (RVFAC), tricuspid annular plane systolic excursion (TAPSE), and in 2D global longitudinal RV strain (2D GLRVS) were observed at weeks 26 and 52 compared to baseline. There was a strong correlation between echo (LVSV, 2D GLRVS, and LVEDV) and cMRI variables, with a moderate correlation for RVSV. Bland-Altman analyses showed a good agreement for LVSV measured by echo versus cMRI, whereas an overestimation in echo-assessed RVSV was observed compared to cMRI (bias of - 15 mL). Hemodynamic and functional variables, as well as safety, were comparable between the Echo sub-study and REPAIR.ConclusionsA good relationship between relevant echo and cMRI parameters was shown. Improvements in RV structure and function with macitentan treatment was observed by echo, consistent with results observed by cMRI in the primary analysis of the REPAIR study. Echo is a valuable complementary method to cMRI, with the potential to non-invasively monitor treatment response at follow-up.Trial registration numberREPAIR NCT02310672.
2024
Torbicki, A., Channick, R., Galiè, N., Kiely, D.G., Moceri, P., Peacock, A., et al. (2024). Effect of Macitentan in Pulmonary Arterial Hypertension and the Relationship Between Echocardiography and cMRI Variables: REPAIR Echocardiography Sub-study Results. CARDIOLOGY AND THERAPY, 13(1), 173-190 [10.1007/s40119-023-00345-2].
Torbicki, A.; Channick, R.; Galiè, N.; Kiely, D. G.; Moceri, P.; Peacock, A.; Swift, A. J.; Tawakol, A.; Vonk Noordegraaf, A.; Flores, D.; Martin, N.;...espandi
File in questo prodotto:
File Dimensione Formato  
Torbicki_2024.pdf

accesso aperto

Tipo: Versione (PDF) editoriale / Version Of Record
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione - Non commerciale (CCBYNC)
Dimensione 1.62 MB
Formato Adobe PDF
1.62 MB Adobe PDF Visualizza/Apri
40119_2023_345_MOESM1_ESM.pdf

accesso aperto

Tipo: File Supplementare
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione - Non commerciale (CCBYNC)
Dimensione 376.49 kB
Formato Adobe PDF
376.49 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/983497
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact