Background: Ceftolozane/tazobactam (C-T) is a novel beta-lactam/beta-lactamase inhibitor combination approved for the treatment of various infections caused by difficult-to-treat Pseudomonas aeruginosa. In critically ill patients, C-T may exhibit significant pharmacokinetic variability, both between individuals and within individuals, warranting therapeutic drug monitoring for clinical purposes. We aim to develop and validate a novel and sensitive analytical method for concurrently determining C and T in human plasma microsamples (3 μL). Methods: The method was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with positive electrospray ionization and multiple reaction monitoring (MRM) detection modes, employing specific mass transitions for both drugs. Sample preparation was simple, and the chromatographic run lasted only 4 minutes. Validation was conducted according to European Medicines Agency (EMA) guidelines, encompassing specificity, sensitivity, linearity, precision, accuracy, matrix effect, extraction recovery, limit of quantification, and drug stability. The validated method was applied to measure C and T in 32 plasma samples collected from critically ill patients with multidrug-resistant, gram-negative, bacterial infections. Results: The method ensured accurate (BIAS% 2.1-9.6 for C and -2.2 to 15.2 for T) and precise intraday CV% for C: 6.7-5.5; for T: 1.3-8.9; interday CV% for C 6.0-10.8; for T 4.1-10.2) measurements of C-T over a wide concentration range (0.2-200.0 mg/L for C and 0.1-100.0 mg/L for T). Overall, the recovery at quality control concentration levels was high for both C and T (mean values: 90-91 for C and 89-92 for T). Analyte stability was satisfactory in both human plasma and extracts under various storage conditions. The clinical applicability of the assay was confirmed by the reliably quantifying C and T in clinical plasma samples. Conclusions: The developed and validated LC-MS/MS method is sensitive and suitable for monitoring C and T in human plasma microsamples.

Conti, M., Giorgi, B., Gatti, M., Viale, P., Pea, F. (2024). Development and Validation of a Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for Therapeutic Drug Monitoring of Ceftolozane and Tazobactam in Human Plasma Microsamples. THERAPEUTIC DRUG MONITORING, 10.1097/FTD.0000000000001236, 1-9 [10.1097/ftd.0000000000001236].

Development and Validation of a Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for Therapeutic Drug Monitoring of Ceftolozane and Tazobactam in Human Plasma Microsamples

Gatti, Milo;Viale, Pierluigi;Pea, Federico
2024

Abstract

Background: Ceftolozane/tazobactam (C-T) is a novel beta-lactam/beta-lactamase inhibitor combination approved for the treatment of various infections caused by difficult-to-treat Pseudomonas aeruginosa. In critically ill patients, C-T may exhibit significant pharmacokinetic variability, both between individuals and within individuals, warranting therapeutic drug monitoring for clinical purposes. We aim to develop and validate a novel and sensitive analytical method for concurrently determining C and T in human plasma microsamples (3 μL). Methods: The method was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with positive electrospray ionization and multiple reaction monitoring (MRM) detection modes, employing specific mass transitions for both drugs. Sample preparation was simple, and the chromatographic run lasted only 4 minutes. Validation was conducted according to European Medicines Agency (EMA) guidelines, encompassing specificity, sensitivity, linearity, precision, accuracy, matrix effect, extraction recovery, limit of quantification, and drug stability. The validated method was applied to measure C and T in 32 plasma samples collected from critically ill patients with multidrug-resistant, gram-negative, bacterial infections. Results: The method ensured accurate (BIAS% 2.1-9.6 for C and -2.2 to 15.2 for T) and precise intraday CV% for C: 6.7-5.5; for T: 1.3-8.9; interday CV% for C 6.0-10.8; for T 4.1-10.2) measurements of C-T over a wide concentration range (0.2-200.0 mg/L for C and 0.1-100.0 mg/L for T). Overall, the recovery at quality control concentration levels was high for both C and T (mean values: 90-91 for C and 89-92 for T). Analyte stability was satisfactory in both human plasma and extracts under various storage conditions. The clinical applicability of the assay was confirmed by the reliably quantifying C and T in clinical plasma samples. Conclusions: The developed and validated LC-MS/MS method is sensitive and suitable for monitoring C and T in human plasma microsamples.
2024
Conti, M., Giorgi, B., Gatti, M., Viale, P., Pea, F. (2024). Development and Validation of a Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for Therapeutic Drug Monitoring of Ceftolozane and Tazobactam in Human Plasma Microsamples. THERAPEUTIC DRUG MONITORING, 10.1097/FTD.0000000000001236, 1-9 [10.1097/ftd.0000000000001236].
Conti, Matteo; Giorgi, Beatrice; Gatti, Milo; Viale, Pierluigi; Pea, Federico
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/979211
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact