A numerical model able to investigate the influence of biomechanical factors on the long-term secondary stability of implants would be extremely useful for the design of new cementless prosthetic devices. A purely biomechanical model of osseo-integration has been developed, formulated as a rule-based adaptation scheme. Due to its complexity, the problem was divided into three steps: preliminary implementation of the model (proof of concept); implementation of the complete model and investigation of the model solution; and model validation. The paper describes the first of these three steps. The model was implemented as a discrete-states machine, and the few parameters required were derived from the literature. It was then applied to a real clinical case. The study was conducted using the frictional contact finite element model of a human femur implanted with a cementless anatomical stem. A stable solution was achieved after between three and 15 iterations for all initial positions considered. Similar initial conditions yielded similar final configurations. The model predicted all initial configurations, with the exception of a partial osseo-integration, ranging between 62% (distal fit) and 78% (proximal fit) of the viable interface. This is in good agreement with the values reported in the literature that never exceed 75%, even in the best conditions, and report better clinical results for proximal fit. For the varus configuration, which lacks cortical support, the algorithm predicted a completed loosening.

Viceconti M., Pancanti A., Dotti M., Traina F., Cristofolini L. (2004). Effect of the initial implant fitting on the predicted secondary stability of a cementless stem. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 42(2), 222-229 [10.1007/BF02344635].

Effect of the initial implant fitting on the predicted secondary stability of a cementless stem

VICECONTI, MARCO;TRAINA, FRANCESCO;CRISTOFOLINI, LUCA
2004

Abstract

A numerical model able to investigate the influence of biomechanical factors on the long-term secondary stability of implants would be extremely useful for the design of new cementless prosthetic devices. A purely biomechanical model of osseo-integration has been developed, formulated as a rule-based adaptation scheme. Due to its complexity, the problem was divided into three steps: preliminary implementation of the model (proof of concept); implementation of the complete model and investigation of the model solution; and model validation. The paper describes the first of these three steps. The model was implemented as a discrete-states machine, and the few parameters required were derived from the literature. It was then applied to a real clinical case. The study was conducted using the frictional contact finite element model of a human femur implanted with a cementless anatomical stem. A stable solution was achieved after between three and 15 iterations for all initial positions considered. Similar initial conditions yielded similar final configurations. The model predicted all initial configurations, with the exception of a partial osseo-integration, ranging between 62% (distal fit) and 78% (proximal fit) of the viable interface. This is in good agreement with the values reported in the literature that never exceed 75%, even in the best conditions, and report better clinical results for proximal fit. For the varus configuration, which lacks cortical support, the algorithm predicted a completed loosening.
2004
Viceconti M., Pancanti A., Dotti M., Traina F., Cristofolini L. (2004). Effect of the initial implant fitting on the predicted secondary stability of a cementless stem. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 42(2), 222-229 [10.1007/BF02344635].
Viceconti M.; Pancanti A.; Dotti M.; Traina F.; Cristofolini L.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/9690
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 23
social impact