IntroductionThe current strategy for modular neck failures in total hip arthroplasty (THA) is calibrated on CrCo neck failures. Stem revision is usually required, but the procedure is challenging and achieves modest outcomes (up to 20% of re-revisions at short-term). No study reports revision strategies and outcomes after Ti neck failures. Aims of the study were to evaluate: (1) demographic and implant features of the cohort to be revised, (2) intra-operative findings and surgical revision strategies and (3) clinical and radiological post-revision outcomes.Materials and methodsHospital database was enquired about revisions due to Ti neck failures in primary THAs. Sixty-five revisions were enrolled (all with the same modular system). Neck exchange was attempted as the first-line treatment. Patients were clinically and radiographically evaluated after revision.ResultsThe revision cohort encompassed fatigue neck fractures occurred 4.4 +/- 2.6 years after THA: patients < 65 years and/or > 80 kg (98.5%) were predominant. Fifty-three neck exchanges were performed (81.5%). Eleven failures required stem revisions (16.9%), generally due to demanding neck extraction. Six complications occurred after neck exchange (11.3%), among them 2 acute infections requiring surgery (3.8%). Among stem revisions, one aseptic loosening and one neck re-fracture (18.5%) required re-revisions. At a mean follow-up of 7.1 +/- 4 years, the neck exchange cohort achieved a mean HHS of 89.1 +/- 6.3 (stem revisions: 84.1 +/- 10.9).ConclusionsRevisions for Ti neck failures were predominantly performed due to fatigue fractures. In case of failures, neck exchange is a feasible procedure in most of the cases, with good outcomes at 7 years.

Mid-term outcomes of revision hip arthroplasty due to titanium modular neck failure / Castagnini, Francesco; Bordini, Barbara; Lucchini, Stefano; Cosentino, Monica; Tassinari, Enrico; Traina, Francesco. - In: ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY. - ISSN 1434-3916. - ELETTRONICO. - 143:9(2023), pp. 5909-5918. [10.1007/s00402-023-04805-1]

Mid-term outcomes of revision hip arthroplasty due to titanium modular neck failure

Castagnini, Francesco;Lucchini, Stefano;Cosentino, Monica;Tassinari, Enrico;Traina, Francesco
2023

Abstract

IntroductionThe current strategy for modular neck failures in total hip arthroplasty (THA) is calibrated on CrCo neck failures. Stem revision is usually required, but the procedure is challenging and achieves modest outcomes (up to 20% of re-revisions at short-term). No study reports revision strategies and outcomes after Ti neck failures. Aims of the study were to evaluate: (1) demographic and implant features of the cohort to be revised, (2) intra-operative findings and surgical revision strategies and (3) clinical and radiological post-revision outcomes.Materials and methodsHospital database was enquired about revisions due to Ti neck failures in primary THAs. Sixty-five revisions were enrolled (all with the same modular system). Neck exchange was attempted as the first-line treatment. Patients were clinically and radiographically evaluated after revision.ResultsThe revision cohort encompassed fatigue neck fractures occurred 4.4 +/- 2.6 years after THA: patients < 65 years and/or > 80 kg (98.5%) were predominant. Fifty-three neck exchanges were performed (81.5%). Eleven failures required stem revisions (16.9%), generally due to demanding neck extraction. Six complications occurred after neck exchange (11.3%), among them 2 acute infections requiring surgery (3.8%). Among stem revisions, one aseptic loosening and one neck re-fracture (18.5%) required re-revisions. At a mean follow-up of 7.1 +/- 4 years, the neck exchange cohort achieved a mean HHS of 89.1 +/- 6.3 (stem revisions: 84.1 +/- 10.9).ConclusionsRevisions for Ti neck failures were predominantly performed due to fatigue fractures. In case of failures, neck exchange is a feasible procedure in most of the cases, with good outcomes at 7 years.
2023
Mid-term outcomes of revision hip arthroplasty due to titanium modular neck failure / Castagnini, Francesco; Bordini, Barbara; Lucchini, Stefano; Cosentino, Monica; Tassinari, Enrico; Traina, Francesco. - In: ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY. - ISSN 1434-3916. - ELETTRONICO. - 143:9(2023), pp. 5909-5918. [10.1007/s00402-023-04805-1]
Castagnini, Francesco; Bordini, Barbara; Lucchini, Stefano; Cosentino, Monica; Tassinari, Enrico; Traina, Francesco
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/964052
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact