Renal micropuncture, which requires the direct access to the renal tubules, has for long time been the technique of choice to measure the single nephron glomerular filtration rate (SNGFR) in animal models. This approach is challenging by virtue of complex animal preparation and numerous technically difficult steps. The introduction of intravital multiphoton microscopy (MPM) offers another approach to the measure of the SNGFR by mean of the high laser-tissue penetration and the optical sectioning capacity. Previous MPM studies measuring SNGFR in vivo relied on fast full-frame acquisition during the filtration process obtainable with high performance resonant scanners. In this study, we describe an innovative linescan–based MPM method. The new method can discriminate SNGFR variations both in conditions of low and high glomerular filtration, and shows results comparable to conventional micropuncture both for rats and mice. Moreover, this novel approach has improved spatial and time resolution and is faster than previous methods, thus enabling the investigation of SNGFR from more tubules and improving options for data-analysis.

Single nephron glomerular filtration rate measured by linescan multiphoton microscopy compared to conventional micropuncture / Costanzo V.; D'Apolito L.; Sardella D.; Iervolino A.; La Manna G.; Capasso G.; Frische S.; Trepiccione F.. - In: PFLÜGERS ARCHIV. - ISSN 0031-6768. - ELETTRONICO. - 474:7(2022), pp. 733-741. [10.1007/s00424-022-02686-8]

Single nephron glomerular filtration rate measured by linescan multiphoton microscopy compared to conventional micropuncture

La Manna G.;
2022

Abstract

Renal micropuncture, which requires the direct access to the renal tubules, has for long time been the technique of choice to measure the single nephron glomerular filtration rate (SNGFR) in animal models. This approach is challenging by virtue of complex animal preparation and numerous technically difficult steps. The introduction of intravital multiphoton microscopy (MPM) offers another approach to the measure of the SNGFR by mean of the high laser-tissue penetration and the optical sectioning capacity. Previous MPM studies measuring SNGFR in vivo relied on fast full-frame acquisition during the filtration process obtainable with high performance resonant scanners. In this study, we describe an innovative linescan–based MPM method. The new method can discriminate SNGFR variations both in conditions of low and high glomerular filtration, and shows results comparable to conventional micropuncture both for rats and mice. Moreover, this novel approach has improved spatial and time resolution and is faster than previous methods, thus enabling the investigation of SNGFR from more tubules and improving options for data-analysis.
2022
Single nephron glomerular filtration rate measured by linescan multiphoton microscopy compared to conventional micropuncture / Costanzo V.; D'Apolito L.; Sardella D.; Iervolino A.; La Manna G.; Capasso G.; Frische S.; Trepiccione F.. - In: PFLÜGERS ARCHIV. - ISSN 0031-6768. - ELETTRONICO. - 474:7(2022), pp. 733-741. [10.1007/s00424-022-02686-8]
Costanzo V.; D'Apolito L.; Sardella D.; Iervolino A.; La Manna G.; Capasso G.; Frische S.; Trepiccione F.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/963595
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? ND
social impact