Purpose: To explore whether extra-short (4-mm) implants could be used to rehabilitate sites where regenerative procedures had failed in order to avoid additional bone grafting. Materials and methods: A retrospective study was conducted among patients who had received extra-short implants after failed regenerative procedures in the posterior atrophic mandible. The research outcomes were complications, implant failure and peri-implant marginal bone loss. Results: The study population was composed of 35 patients with 103 extra-short implants placed after the failure of different reconstructive approaches. The mean follow-up duration was 41.3 ± 21.4 months post-loading. Two implants failed, leading to a failure rate of 1.94% (95% confidence interval 0.24%-6.84%) and an implant survival rate of 98.06%. The mean amount of marginal bone loss at 5 years post-loading was 0.32 ± 0.32 mm. It was significantly lower in extra-short implants placed in regenerative sites that had previously received a loaded long implant (P = 0.004). Failure of guided bone regeneration before placement of short implants tended to lead to the highest annual rate of marginal bone loss (P = 0.089). The overall rate of biological and prosthetic complications was 6.79% (95% confidence interval 1.94%-11.70%) and 3.88% (95% confidence interval 1.07%-9.65%), respectively. The success rate was 86.4% (95% confidence interval 65.10%-97.10%) after 5 years of loading. Conclusions: Within the limitations of this study, extra-short implants seem to be a good clinical option to manage reconstructive surgical failures, reducing surgical invasiveness and rehabilitation time.

Barausse, C., Ravidà, A., Bonifazi, L., Pistilli, R., Saleh, M.H.A., Gasparro, R., et al. (2023). Extra-short (4-mm) implants placed after regenerative failures in the posterior atrophic mandible: A retrospective study. INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 16(1), 31-38.

Extra-short (4-mm) implants placed after regenerative failures in the posterior atrophic mandible: A retrospective study

Barausse, Carlo;Bonifazi, Lorenzo;Felice, Pietro
2023

Abstract

Purpose: To explore whether extra-short (4-mm) implants could be used to rehabilitate sites where regenerative procedures had failed in order to avoid additional bone grafting. Materials and methods: A retrospective study was conducted among patients who had received extra-short implants after failed regenerative procedures in the posterior atrophic mandible. The research outcomes were complications, implant failure and peri-implant marginal bone loss. Results: The study population was composed of 35 patients with 103 extra-short implants placed after the failure of different reconstructive approaches. The mean follow-up duration was 41.3 ± 21.4 months post-loading. Two implants failed, leading to a failure rate of 1.94% (95% confidence interval 0.24%-6.84%) and an implant survival rate of 98.06%. The mean amount of marginal bone loss at 5 years post-loading was 0.32 ± 0.32 mm. It was significantly lower in extra-short implants placed in regenerative sites that had previously received a loaded long implant (P = 0.004). Failure of guided bone regeneration before placement of short implants tended to lead to the highest annual rate of marginal bone loss (P = 0.089). The overall rate of biological and prosthetic complications was 6.79% (95% confidence interval 1.94%-11.70%) and 3.88% (95% confidence interval 1.07%-9.65%), respectively. The success rate was 86.4% (95% confidence interval 65.10%-97.10%) after 5 years of loading. Conclusions: Within the limitations of this study, extra-short implants seem to be a good clinical option to manage reconstructive surgical failures, reducing surgical invasiveness and rehabilitation time.
2023
Barausse, C., Ravidà, A., Bonifazi, L., Pistilli, R., Saleh, M.H.A., Gasparro, R., et al. (2023). Extra-short (4-mm) implants placed after regenerative failures in the posterior atrophic mandible: A retrospective study. INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 16(1), 31-38.
Barausse, Carlo; Ravidà, Andrea; Bonifazi, Lorenzo; Pistilli, Roberto; Saleh, Muhammad H A; Gasparro, Roberta; Sammartino, Gilberto; Wang, Hom-Lay; Fe...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/962908
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact