While the ITER magnet system assembly is progressing, models are being developed to predict the performances of the coils in support of the preparation of commissioning and operation. In particular, the AC losses generated in the coils during a plasma scenario need to be estimated as input to thermo-hydraulic performance simulations. The largest AC losses during plasma operation are expected in the CS and PF coils. This paper discusses the results of simulations of AC losses in these coils during a representative ITER plasma pulse. These calculations also take into account the electromagnetic screening provided by the ITER passive structures, most importantly the vacuum vessel, discussing its impact on the conductor AC losses. The results will also be compared to earlier predictions. Finally, the CS and PF coil AC losses expected during commissioning will be briefly discussed.
Bauer P., Breschi M., Cavallucci L., Duchateau J.-L., Gauthier F., Ilyin Y., et al. (2023). AC Losses Calculations for the ITER CS and PF Magnet Systems during Plasma Operation. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 33(5), 1-5 [10.1109/TASC.2023.3262214].
AC Losses Calculations for the ITER CS and PF Magnet Systems during Plasma Operation
Breschi M.;Cavallucci L.;
2023
Abstract
While the ITER magnet system assembly is progressing, models are being developed to predict the performances of the coils in support of the preparation of commissioning and operation. In particular, the AC losses generated in the coils during a plasma scenario need to be estimated as input to thermo-hydraulic performance simulations. The largest AC losses during plasma operation are expected in the CS and PF coils. This paper discusses the results of simulations of AC losses in these coils during a representative ITER plasma pulse. These calculations also take into account the electromagnetic screening provided by the ITER passive structures, most importantly the vacuum vessel, discussing its impact on the conductor AC losses. The results will also be compared to earlier predictions. Finally, the CS and PF coil AC losses expected during commissioning will be briefly discussed.File | Dimensione | Formato | |
---|---|---|---|
PBR_ASC22_Paper_AC_Loss_CS_draft_v1erevjld.pdf
accesso aperto
Tipo:
Postprint
Licenza:
Licenza per accesso libero gratuito
Dimensione
617.43 kB
Formato
Adobe PDF
|
617.43 kB | Adobe PDF | Visualizza/Apri |