During the 2012 Emilia earthquake, several precast RC industrial build-ings were damaged or collapsed due to a strong rotational response triggered by the presence of a single or few eccentric walls within the regular mesh of columns. The objective of this work is to analyse the torsional effects induced by an eccentric wall in one-storey frame structures, and to provide formulas for a quick estimation of the displacement of the flexible side. Starting from the typical structural scheme of in-dustrial one-storey structures consisting of a regular grid of uniformly spaced col-umns, a stiff lateral shear wall has been added to make the structure asymmetric. A response parameter (displacement amplification factor), defined as the ratio be-tween the translational displacement of the irregular structure over the translational displacement of the corresponding equivalent regular structure without the added wall/s, is introduced to evaluate the torsional response of the system. An analytical formula is derived by means of a linear static analysis. The results indicate that the presence of a shear wall, even though significantly stiffer than the columns with respect to lateral action, does not always lead to a reduction of the seismic displace-ment demand in the columns.

A simplified static analysis of the torsional effects induced by eccentric walls in one-storey frame structures

Stefano Silvestri
Primo
;
Michele Palermo;Giada Gasparini;Tomaso Trombetti
2023

Abstract

During the 2012 Emilia earthquake, several precast RC industrial build-ings were damaged or collapsed due to a strong rotational response triggered by the presence of a single or few eccentric walls within the regular mesh of columns. The objective of this work is to analyse the torsional effects induced by an eccentric wall in one-storey frame structures, and to provide formulas for a quick estimation of the displacement of the flexible side. Starting from the typical structural scheme of in-dustrial one-storey structures consisting of a regular grid of uniformly spaced col-umns, a stiff lateral shear wall has been added to make the structure asymmetric. A response parameter (displacement amplification factor), defined as the ratio be-tween the translational displacement of the irregular structure over the translational displacement of the corresponding equivalent regular structure without the added wall/s, is introduced to evaluate the torsional response of the system. An analytical formula is derived by means of a linear static analysis. The results indicate that the presence of a shear wall, even though significantly stiffer than the columns with respect to lateral action, does not always lead to a reduction of the seismic displace-ment demand in the columns.
2023
Proceedings of the 10th European Workshop on the Seismic Behaviour of Irregular and Complex Structures (10EWICS)
1
10
Stefano Silvestri; Michele Palermo; Giada Gasparini; Tomaso Trombetti
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/962078
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact