Left main coronary artery percutaneous coronary intervention is particularly complex when stenting across the distal bifurcation is required in the presence of a diameter mismatch between the proximal main and distal branches. A suboptimal procedural result increases the risk of thrombosis and restenosis. Considering the paucity of data published on this topic, our objective was to provide technical solutions to deal with this complex anatomy. We described four cases showing the use of devices and techniques which allowed us to overcome a diameter discrepancy between adjacent coronary segments: (1) self-expanding nitinol stent; (2) stent platform with noteworthy expansion capacity; (3) the 'extended skirt' technique; (4) the 'trouser-leg' technique. In conclusion, the use of specific strategies and devices allows a safe and effective approach to be used to perform treatment that respects the coronary anatomy, and to optimize percutaneous coronary intervention results in complex scenarios.

How to deal with vessel diameter mismatch in left main bifurcation stenting / Dall'Ara G; Grotti S; Compagnone M; Spartà D; Guerrieri G; Galvani M; Tarantino FF. - In: JOURNAL OF CARDIOVASCULAR MEDICINE. - ISSN 1558-2027. - STAMPA. - 23:9(2022), pp. 600-607. [10.2459/jcm.0000000000001356]

How to deal with vessel diameter mismatch in left main bifurcation stenting

Dall'Ara G
;
Compagnone M;Galvani M;
2022

Abstract

Left main coronary artery percutaneous coronary intervention is particularly complex when stenting across the distal bifurcation is required in the presence of a diameter mismatch between the proximal main and distal branches. A suboptimal procedural result increases the risk of thrombosis and restenosis. Considering the paucity of data published on this topic, our objective was to provide technical solutions to deal with this complex anatomy. We described four cases showing the use of devices and techniques which allowed us to overcome a diameter discrepancy between adjacent coronary segments: (1) self-expanding nitinol stent; (2) stent platform with noteworthy expansion capacity; (3) the 'extended skirt' technique; (4) the 'trouser-leg' technique. In conclusion, the use of specific strategies and devices allows a safe and effective approach to be used to perform treatment that respects the coronary anatomy, and to optimize percutaneous coronary intervention results in complex scenarios.
2022
How to deal with vessel diameter mismatch in left main bifurcation stenting / Dall'Ara G; Grotti S; Compagnone M; Spartà D; Guerrieri G; Galvani M; Tarantino FF. - In: JOURNAL OF CARDIOVASCULAR MEDICINE. - ISSN 1558-2027. - STAMPA. - 23:9(2022), pp. 600-607. [10.2459/jcm.0000000000001356]
Dall'Ara G; Grotti S; Compagnone M; Spartà D; Guerrieri G; Galvani M; Tarantino FF
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/961963
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact